EUVIMEDEUVIMED entdecken
StudienprotokollOpen Access · CC BY 4.0

Test-retest reliability of joint space width measurements using the standardized MOST4 XFI knee radiography protocol

Nasim Nosrati Nia, John A Lynch, Michael C Nevitt, Naga Harshita Degala, Neil A Segal

Osteoarthritis Imaging · 2026-10 · 100480

DOI: 10.1016/j.ostima.2026.100480 ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift Osteoarthritis Imaging, 2026-10. Verfasst von Nasim Nosrati Nia und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Medicine & Rehabilitation, The University of Kansas, Kansas City, KS, United States. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The University of Kansas School of Medicine.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To evaluate the short-term test-retest reliability of two-dimensional joint space width (JSW) measurements acquired using the standardized Multicenter Osteoarthritis Study (MOST) radiographic protocol with a cone-beam CT system. DESIGN: This cross-sectional, observational test-retest reliability study included 14 adults (28 knees) aged 50-79 years with Kellgren-Lawrence grades 0-4 who met MOST inclusion criteria. Bilateral posteroanterior weight-bearing radiographs were acquired using an XFI scanner (Planmed Oy, Helsinki, Finland) with a tilted Perspex positioning frame to align the tibial plateau parallel to the central X-ray beam. JSW was measured at 50-90% of the distance from the tibial spine to the outer tibial plateau in both the medial and lateral tibiofemoral compartments. Test-retest reliability over a two-week interval was assessed using Shrout-Fleiss intraclass correlation coefficients (ICC(2,1)) and limits of agreement (LoA). RESULTS: Medial compartment JSW measurements demonstrated excellent test-retest reliability, with ICCs ranging from 0.92 to 0.96. Lateral compartment measurements showed good reliability, with ICCs ranging from 0.76 to 0.87. The narrowest LoA were observed at the 80% measurement location in the medial compartment (-0.81 to 0.62 mm) and at the 90% location in the lateral compartment (-0.14 to 2.26 mm). CONCLUSIONS: The MOST XFI radiographic protocol provides reliable and standardized measurements of tibiofemoral JSW in both the medial and lateral compartments. These findings support its use in longitudinal studies and clinical research evaluating structural progression and therapeutic response in knee osteoarthritis.

Schlagwörter

Stichwörter der Autor:innen

Cone-beam computed tomographyKneeKnee jointObserver variationOsteoarthritis

Autor:innen und Institutionen

  • Department of Physical Medicine & Rehabilitation, The University of Kansas, Kansas City, KS, United States.
  • Department of Epidemiology & Biostatistics, University of California San Francisco, San Francisco, CA, United States.
  • Department of Physical Medicine & Rehabilitation, The University of Kansas, Kansas City, KS, United States; Department of Epidemiology, The University of Iowa, Iowa City, IA, United States. Electronic address: segal-res…

Förderung

  • The University of Kansas School of Medicine

Zitieren

APA

Nosrati Nia, N., Lynch, J. A., Nevitt, M. C., Degala, N. H., & Segal, N. A. (2026). Test-retest reliability of joint space width measurements using the standardized MOST4 XFI knee radiography protocol. Osteoarthritis Imaging, 100480. https://doi.org/10.1016/j.ostima.2026.100480

Vancouver

Nosrati Nia N, Lynch JA, Nevitt MC, Degala NH, Segal NA. Test-retest reliability of joint space width measurements using the standardized MOST4 XFI knee radiography protocol. Osteoarthritis Imaging. 2026:100480. doi:10.1016/j.ostima.2026.100480

BibTeX
@article{NosratiNia2026,
  author = {Nosrati Nia, Nasim and Lynch, John A and Nevitt, Michael C and Degala, Naga Harshita and Segal, Neil A},
  title = {Test-retest reliability of joint space width measurements using the standardized MOST4 XFI knee radiography protocol},
  journal = {Osteoarthritis Imaging},
  year = {2026},
  pages = {100480},
  doi = {10.1016/j.ostima.2026.100480}
}
Kostenlos starten →