Positioning accuracy and facet joints violation after percutaneous pedicle screws placement with robot-assisted versus fluoroscopy-guided technique: Systematic review and meta-analysis
Journal of Neurosciences in Rural Practice · 27.07.2023 · 14 · 406-412
DOI: 10.25259/jnrp_147_2023 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Neurosciences in Rural Practice, online erschienen am 27.07.2023. Verfasst von Andrea Perna und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Geriatrics and Orthopaedics Sciences, IRCCS Fondazione Policlinico Universitario Agostino Gemelli, Roma, Italy. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Introduction
Minimally invasive spine surgery became the gold standard for the treatment of many spinal diseases. Only a few comparative studies were performed regarding the superiority of robotic-assisted (RA) surgery over fluoroscopic guidance (FG) surgery during percutaneous pedicle screws placement. Therefore, the aim of the present study was to conduct a systematic literature review and meta-analysis to evaluate the accuracy and potential advantages of RA compared with FG. Material and Methods: This study is a systematic literature review conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. The review questions were formulated following the PICO scheme. Measured outcomes were presented using Forest plots. Heterogeneity among the included studies was assessed using the χ 2 test, and the I 2 statistic was utilized to estimate the proportion of total variation among the studies. A value exceeding 50% was considered indicative of substantial heterogeneity.
Results
Seven studies that met inclusion criteria were finally included in this meta-analysis. These seven studies include: 447 patients, 228 patients (931 screws) treated with robotic guide, and 219 patients (767 pedicle screws) using fluoroscopic guide, with a mean age of 55.2. The percentages of clinically acceptable screws were 94.3% in the robot-assisted group and 89% in the fluoroscopic guided group. The percentages of non-acceptable screws were 5.7% in the robot-assisted group and 11% in the fluoroscopic-guided group.
Discussion
Significant differences were observed between the two groups in terms of radiographic and clinical outcomes, with the robotic-assisted pedicle screw group exhibiting longer operative times. Robot technology serves as a valuable tool for assisting surgeons in challenging scenarios such as anatomical variants or patients with spinal deformities, ensuring accurate screw placement.
Conclusion
The accuracy of pedicle screw placement with robotic technology is higher than with FG. In fact, the robotic approach allows significantly lower complication rates, fewer cases of violation of the proximal articular facet, less intraoperative exposure to radiation, even if it requires longer surgical times than the FG technique.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Geriatrics and Orthopaedics Sciences, IRCCS Fondazione Policlinico Universitario Agostino Gemelli, Roma, Italy.
- Department of Orthopedics and Trauma Surgery, Fondazione Casa Sollievo Della Sofferenza IRCCS, San Giovanni Rotondo, Italy.
ORCID-Profile: Maria Ilaria Borruto
Zitieren
APA
Perna, A., Velluto, C., Smakaj, A., Tamburrelli, F., Borruto, M. I., Santagada, D. A., Gorgoglione, F. L., Liuzza, F., & Proietti, L. (2023). Positioning accuracy and facet joints violation after percutaneous pedicle screws placement with robot-assisted versus fluoroscopy-guided technique: Systematic review and meta-analysis. Journal of Neurosciences in Rural Practice, 14, 406-412. https://doi.org/10.25259/jnrp_147_2023
Vancouver
Perna A, Velluto C, Smakaj A, Tamburrelli F, Borruto MI, Santagada DA, et al. Positioning accuracy and facet joints violation after percutaneous pedicle screws placement with robot-assisted versus fluoroscopy-guided technique: Systematic review and meta-analysis. Journal of Neurosciences in Rural Practice. 2023;14:406-412. doi:10.25259/jnrp_147_2023
BibTeX
@article{Perna2023,
author = {Perna, Andrea and Velluto, Calogero and Smakaj, Amarildo and Tamburrelli, Francesco and Borruto, Maria Ilaria and Santagada, Domenico Alessandro and Gorgoglione, Franco Lucio and Liuzza, Francesco and Proietti, Luca},
title = {Positioning accuracy and facet joints violation after percutaneous pedicle screws placement with robot-assisted versus fluoroscopy-guided technique: Systematic review and meta-analysis},
journal = {Journal of Neurosciences in Rural Practice},
year = {2023},
volume = {14},
pages = {406--412},
doi = {10.25259/jnrp_147_2023}
}