Comparative accuracy of Barrett true-K and Haigis-L formulas for intraocular lens power calculation in post-laser-assisted in situ keratomileusis cataract surgery
Global Journal of Cataract Surgery and Research in Ophthalmology · 11.04.2026 · 5 · 117-125
DOI: 10.25259/gjcsro_42_2025 ↗Kurz gefasst
Fachartikel in der Zeitschrift Global Journal of Cataract Surgery and Research in Ophthalmology, online erschienen am 11.04.2026. Verfasst von Ankit Sanjay Varshney und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
Objectives
The objective of the study is to compare the refractive accuracy of the Barrett true-K total keratometry (TK) and Haigis-L intraocular lens (IOLs) power calculation formulas in post-laser-assisted in situ keratomileusis (LASIK) eyes undergoing cataract surgery. Materials and Methods: This retrospective comparative study included 60 eyes of 40 patients with a history of LASIK who underwent uneventful phacoemulsification with monofocal IOL implantation at a tertiary eye care centre in Gujarat, India (2024–2025). IOL power was calculated using Barrett True-K TK in 30 eyes (Group 1) and Haigis-L in 30 eyes (Group 2). The cohort comprised 44 myopic LASIK eyes (73.3%) and 16 hyperopic LASIK eyes (26.7%). Outcome measures included post-operative uncorrected distance visual acuity (UDVA), best-corrected visual acuity (BCVA), spherical equivalent (SE), mean absolute error (MAE), prediction error (PE) and residual astigmatism. PE was defined as achieved minus predicted post-operative SE. Statistical analysis included paired and independent t -tests or non-parametric equivalents, Chi-square tests for categorical variables and age-adjusted analysis of covariance with generalised estimating equations to account for baseline age differences and inter-eye correlation.
Results
Both formulas produced significant post-operative improvement in UDVA and BCVA (all p < 0.001). At 1 month, UDVA was significantly better with Barrett true-K TK (0.04 ± 0.08 logMAR) compared with Haigis-L (0.12 ± 0.19 logMAR; p = 0.021), while BCVA was comparable between groups (0.01 ± 0.03 logMAR; p = 0.82). Mean post-operative SE was closer to emmetropia with Barrett true-K TK (−0.29 ± 0.34 D) than with Haigis-L (−0.44 ± 0.54 D). Barrett True-K TK demonstrated significantly lower MAE (0.34 ± 0.12 D) compared with Haigis-L (0.54 ± 0.21 D; p = 0.038) and a higher proportion of eyes within ±0.50 D of target refraction (80% vs. 63%). Subgroup analysis showed consistently lower MAE with Barrett true-K TK across axial length categories and LASIK types, with greater variability observed in post-hyperopic LASIK eyes.
Conclusion
Both formulas yielded satisfactory outcomes in post-LASIK cataract patients; however, Barrett true-K TK demonstrated superior refractive predictability and accuracy. Its independence from historical refractive data supports its use as the preferred IOL calculation formula in post-refractive eyes.
Zitieren
APA
Varshney, A. S., Ojha, M., Patel, C. V., & Chauhan, M. D. (2026). Comparative accuracy of Barrett true-K and Haigis-L formulas for intraocular lens power calculation in post-laser-assisted in situ keratomileusis cataract surgery. Global Journal of Cataract Surgery and Research in Ophthalmology, 5, 117-125. https://doi.org/10.25259/gjcsro_42_2025
Vancouver
Varshney AS, Ojha M, Patel CV, Chauhan MD. Comparative accuracy of Barrett true-K and Haigis-L formulas for intraocular lens power calculation in post-laser-assisted in situ keratomileusis cataract surgery. Global Journal of Cataract Surgery and Research in Ophthalmology. 2026;5:117-125. doi:10.25259/gjcsro_42_2025
BibTeX
@article{Varshney2026,
author = {Varshney, Ankit Sanjay and Ojha, Monika and Patel, Chetna V. and Chauhan, Mahendrasinh D.},
title = {Comparative accuracy of Barrett true-K and Haigis-L formulas for intraocular lens power calculation in post-laser-assisted in situ keratomileusis cataract surgery},
journal = {Global Journal of Cataract Surgery and Research in Ophthalmology},
year = {2026},
volume = {5},
pages = {117--125},
doi = {10.25259/gjcsro_42_2025}
}
EUVIMED