Objectives

This study comparatively evaluated the mechanical properties of four commercially available, directly three-dimensional (3D) printed clear aligner materials by analyzing tensile behavior, flexural properties, and surface hardness. Material and Methods: Four direct-print clear aligner resins were included: Custom resin solutions (CRS), LuxCreo, Rayform 4D clear aligner resin, and PowerResins clear smile resin. Specimens were fabricated according to the manufacturers’ protocols with a standardized thickness of 0.70 mm and 50 µm layer thickness in vertical orientation. Tensile ( n = 5), three-point bending ( n = 5), and Shore D hardness ( n = 10) tests were performed at room temperature (23°C) at the accredited laboratories of TÜBİTAK Marmara Research Center. Statistical analysis was performed using one-way analysis of variance followed by Sidak’s multiple comparisons test ( p < 0.05).

Results

Significant differences were found among all materials for all tested parameters ( p < 0.0001). PowerResins showed the highest elastic modulus (2187.7 ± 315.8 MPa), tensile strength (51.5 ± 2.9 MPa), flexural modulus (1609.7 ± 95.6 MPa), flexural strength (71.9 ± 2.9 MPa), and Shore D hardness (87.3 ± 0.9), indicating superior rigidity. LuxCreo demonstrated the highest elongation at break (118.4 ± 10.7%), suggesting greater flexibility and ductility. Rayform 4D showed intermediate mechanical behavior, whereas CRS generally exhibited lower flexural resistance.

Conclusion

Directly printed clear aligner materials exhibit significant variability in mechanical properties. PowerResins may be more suitable for cases requiring greater rigidity and force delivery, whereas LuxCreo may be preferable when flexibility and patient comfort are prioritized. Material selection should be based on specific orthodontic treatment objectives and clinical biomechanical requirements.

Zitieren

APA

Cakir, B. G., Tutka, N., & Artuc, A. M. (2026). Comparative evaluation of mechanical properties of directly 3D-printed clear aligner materials. APOS Trends in Orthodontics, 16, 245-251. https://doi.org/10.25259/apos_133_2026

Vancouver

Cakir BG, Tutka N, Artuc AM. Comparative evaluation of mechanical properties of directly 3D-printed clear aligner materials. APOS Trends in Orthodontics. 2026;16:245-251. doi:10.25259/apos_133_2026

BibTeX
@article{Cakir2026,
  author = {Cakir, Betul Gulhan and Tutka, Nida and Artuc, Ahmet Murat},
  title = {Comparative evaluation of mechanical properties of directly 3D-printed clear aligner materials},
  journal = {APOS Trends in Orthodontics},
  year = {2026},
  volume = {16},
  pages = {245--251},
  doi = {10.25259/apos_133_2026}
}
Kostenlos starten →