EUVIMEDEUVIMED entdecken
Crossref

TONO-GUN: Design and Development of a Miniature Non-Contact Air-Puff Tonometer for Intraocular Pressure Measurement

Jackson Daniel, Sanjai Prasath M, Kesavan S, Mouriya M

International Journal of Drug Delivery Technology · 29.05.2026 · 16 (37s)

DOI: 10.25258/ijddt.16.37s.28 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 29.05.2026. Verfasst von Jackson Daniel und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Glaucoma remains one of the primary causes of irreversible blindness, and early detection along with monitoring of the condition is crucially dependent on the measurement of intraocular pressure. Conventional clinical-use tonometer are often bulky, expensive, and not suitable for personal use or measurements outside a clinic setting. The aim of this paper is to present a compact, non-contact air-puff tonometer for easy, portable, and hygienic IOP measurement.The corneal deformation in the proposed device is produced by a controlled air puff. A momentary pulse of air is applied on the surface of the cornea, causing it briefly to flatten. The air flow is then ceased and the pressure applied is measured and converted to millibar IOP values. Included in the system are a small air pump, pressure sensor, optical lighting, configuration for beam splitting, and a system for detection of the flattening of the cornea. TONO-GUN was to be designed in such a way that it would be easy to use, portable, and noninvasive. Its aim is providing an inexpensive, easily accessible alternative for screening of IOP in clinics, home care settings, and rural healthcare.

Zitieren

APA

Daniel, J., M, S. P., S, K., & M, M. (2026). TONO-GUN: Design and Development of a Miniature Non-Contact Air-Puff Tonometer for Intraocular Pressure Measurement. International Journal of Drug Delivery Technology, 16(37s). https://doi.org/10.25258/ijddt.16.37s.28

Vancouver

Daniel J, M SP, S K, M M. TONO-GUN: Design and Development of a Miniature Non-Contact Air-Puff Tonometer for Intraocular Pressure Measurement. International Journal of Drug Delivery Technology. 2026;16(37s). doi:10.25258/ijddt.16.37s.28

BibTeX
@article{Daniel2026,
  author = {Daniel, Jackson and M, Sanjai Prasath and S, Kesavan and M, Mouriya},
  title = {TONO-GUN: Design and Development of a Miniature Non-Contact Air-Puff Tonometer for Intraocular Pressure Measurement},
  journal = {International Journal of Drug Delivery Technology},
  year = {2026},
  volume = {16},
  number = {37s},
  doi = {10.25258/ijddt.16.37s.28}
}
Kostenlos starten →