EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

From the Goldman Tonometer to Wearable Sensors: The Evolution of Intraocular Pressure Measurement Technology

Jie Fang, Panpan Jiang, Yuning Lei, Jinjie Duan, Qiong Wang, Yuxiang Wu

Structural Control and Health Monitoring · 2026-01 · 2026 (1)

DOI: 10.1155/stc/9125379 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Structural Control and Health Monitoring, online erschienen am 23.08.2026. Verfasst von Jie Fang und 5 weiteren Autor:innen. Die Arbeit nennt 139 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hubei Provincial Department of Education.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fluctuations in intraocular pressure (IOP) are associated with various physiological conditions, including systemic hypertension, diabetes, and glaucoma. Monitoring IOP fluctuations enables early diagnosis and prevention of certain diseases. Among these, IOP represents the most significant controllable risk factor for glaucoma, making its monitoring crucial for the early diagnosis and treatment of the condition. In recent years, evolving understanding of IOP fluctuations has driven continuous advancements in measurement technologies and methodologies. This paper comprehensively reviews the association between IOP and physiological diseases, the development of traditional discontinuous IOP measurement methods, and research progress in emerging continuous IOP monitoring techniques. Regarding physical principles, the measurement mechanisms of different IOP techniques are elucidated. For clinical applications, a systematic comparison of the use cases and product advantages of various tonometers is presented. Finally, challenges in accuracy, stability, and safety within continuous IOP monitoring are addressed, along with proposed solutions. Future research directions are explored, including integrating deep learning for analyzing continuous IOP monitoring data and predicting risks.

Förderung

  • Hubei Provincial Department of Education

Zitieren

APA

Fang, J., Jiang, P., Lei, Y., Duan, J., Wang, Q., & Wu, Y. (2026). From the Goldman Tonometer to Wearable Sensors: The Evolution of Intraocular Pressure Measurement Technology. Structural Control and Health Monitoring, 2026(1). https://doi.org/10.1155/stc/9125379

Vancouver

Fang J, Jiang P, Lei Y, Duan J, Wang Q, Wu Y. From the Goldman Tonometer to Wearable Sensors: The Evolution of Intraocular Pressure Measurement Technology. Structural Control and Health Monitoring. 2026;2026(1). doi:10.1155/stc/9125379

BibTeX
@article{Fang2026,
  author = {Fang, Jie and Jiang, Panpan and Lei, Yuning and Duan, Jinjie and Wang, Qiong and Wu, Yuxiang},
  title = {From the Goldman Tonometer to Wearable Sensors: The Evolution of Intraocular Pressure Measurement Technology},
  journal = {Structural Control and Health Monitoring},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1155/stc/9125379}
}
Kostenlos starten →