EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

The addition of a Rumel suture minimizes entry portal gas leakage of laparoscopic ports: a canine cadaveric study

Erica Rehnblom, Adrien Aertsens

American Journal of Veterinary Research · 2025

DOI: 10.2460/ajvr.25.04.0142 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Veterinary Research, 2025. Verfasst von Erica Rehnblom und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Iowa State University, Ames, IA. Hauptthemen laut MEDLINE: Laparoscopy, Suture Techniques, Sutures. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare periportal gas leakage of 3 laparoscopic cannulas with and without a Rumel suture.

Methods

This was a descriptive canine cadaveric (n = 10) study performed from October 28 to 29, 2023. Five portal configurations were compared: a smooth (S) and threaded (T) cannula with and without a Rumel suture (SR and TR, respectively) and a balloon (B) cannula. Each configuration was inserted once each on midline and paramedian, the abdomen was insufflated to 10 mm Hg, and the cannula was manipulated for 2 minutes. Gas leakage was recorded by using a soap bubble test and the duration of insufflation (seconds).

Results

Regardless of location, SR and TR had the fewest number of leaks and duration of insufflation. When comparing midline portal locations, there were no demonstrable differences in duration of insufflation between portal configurations. When comparing the estimated difference in duration of insufflation for paramedian portal locations, SR had a lower duration of insufflation compared to T by 67.0 seconds and S by 46.2 seconds, and TR had a lower duration of insufflation compared to T by 66.5 seconds and S by 45.7 seconds. Between midline and paramedian, the S configuration had a statistically significant decrease in duration of insufflation on midline compared to paramedian by 30.4 seconds. The T configuration had a significantly lower duration of insufflation on midline compared to paramedian by 51.1 seconds.

Conclusions

Gas leakage varies between portals, and adding a Rumel suture decreased gas leakage. Clinical Relevance Surrounding stainless steel entry portals with a Rumel suture could help minimize insufflation leakage of the cannula.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LaparoscopySuture TechniquesSuturesAnimalsDogsCadaverInsufflationCannula

Stichwörter der Autor:innen

ballooncaninelaparoscopyleakportal

Autor:innen und Institutionen

  • Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Iowa State University, Ames, IA.
  • Surgery Department, Centre Hospitalier Vétérinaire Aquivet, Mérignac, France.

Zitieren

APA

Rehnblom, E., & Aertsens, A. (2025). The addition of a Rumel suture minimizes entry portal gas leakage of laparoscopic ports: a canine cadaveric study. American Journal of Veterinary Research. https://doi.org/10.2460/ajvr.25.04.0142

Vancouver

Rehnblom E, Aertsens A. The addition of a Rumel suture minimizes entry portal gas leakage of laparoscopic ports: a canine cadaveric study. American Journal of Veterinary Research. 2025. doi:10.2460/ajvr.25.04.0142

BibTeX
@article{Rehnblom2025,
  author = {Rehnblom, Erica and Aertsens, Adrien},
  title = {The addition of a Rumel suture minimizes entry portal gas leakage of laparoscopic ports: a canine cadaveric study},
  journal = {American Journal of Veterinary Research},
  year = {2025},
  doi = {10.2460/ajvr.25.04.0142}
}
Kostenlos starten →