EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Effects of cyanoacrylate on leakage pressures of cooled canine cadaveric jejunal enterotomies

Jamie-Leigh Thompson iD, Lucy Miller, Kelly Bowlt Blacklock iD

Veterinary Surgery · 2024

DOI: 10.1111/vsu.14059 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Surgery, 2024. Verfasst von Jamie-Leigh Thompson und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Small Animal Surgery, The Royal Dick School of Veterinary Studies, Edinburgh, Scotland. Hauptthemen laut MEDLINE: Jejunum, Dog Diseases. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Advanced Medical Solutions Group Ltd..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare the intraluminal initial and maximal pressures of enterotomies closed using three different techniques (single‐layer appositional continuous closure; closure with cyanoacrylate; a single‐layer appositional closure augmented with cyanoacrylate) in a cooled canine cadaveric jejunal model and to report the initial leak location in all samples. Study design Experimental, ex‐vivo study. Sample population Grossly normal chilled small intestine segments from three canine cadavers.

Methods

A total of 45 chilled jejunal segments ( n = 15 segments/group) were assigned to a handsewn group (HSE), a cyanoacrylate only group (CE) and a handsewn and cyanoacrylate group (HS + CE). A 2 cm antimesenteric enterotomy was performed and closure with one of the above techniques. Initial leakage pressures (ILP), maximal intraluminal pressures (MIP) and initial leakage location were recorded by a single observer.

Results

Handsewn enterotomies leaked at higher ILP when augmented with cyanoacrylate (83.3 ± 4.6 mmHg, p < .001) compared to both the HSE group (43.8 ± 5.3 mmHg) and the CE group (18.6 ± 3.5 mmHg). Those sealed with cyanoacrylate only leaked at a lower MIP compared with the other groups ( p < .001). Maximal intraluminal pressures did not differ between handsewn enterotomies, whether augmented or not ( p = .19).

Conclusion

Reinforcement of a sutured enterotomy closure with cyanoacrylate was easy to perform and resulted in significantly increased initial leak pressures in cadaveric jejunum. Clinical significance The increased leakage pressures achieved by reinforcing enterotomies with cyanoacrylate could consequently reduce the incidence of postoperative intestinal leakage following an enterotomy and may result in reduced patient morbidity or mortality.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

JejunumDog DiseasesAnimalsDogsCyanoacrylatesSuturesSuture TechniquesCadaver

Substanzen

Cyanoacrylates

Autor:innen und Institutionen

  • Department of Small Animal Surgery, The Royal Dick School of Veterinary Studies, Edinburgh, Scotland.
  • Department of Anesthesia and Analgesia, The Royal Dick School of Veterinary Studies, Edinburgh, Scotland.

ORCID-Profile: Jamie-Leigh Thompson, Kelly Bowlt Blacklock

Förderung

  • Advanced Medical Solutions Group Ltd.

Zitieren

APA

Thompson, J. L., Miller, L., & Bowlt Blacklock, K. (2024). Effects of cyanoacrylate on leakage pressures of cooled canine cadaveric jejunal enterotomies. Veterinary Surgery. https://doi.org/10.1111/vsu.14059

Vancouver

Thompson JL, Miller L, Bowlt Blacklock K. Effects of cyanoacrylate on leakage pressures of cooled canine cadaveric jejunal enterotomies. Veterinary Surgery. 2024. doi:10.1111/vsu.14059

BibTeX
@article{Thompson2024,
  author = {Thompson, Jamie-Leigh and Miller, Lucy and Bowlt Blacklock, Kelly},
  title = {Effects of cyanoacrylate on leakage pressures of cooled canine cadaveric jejunal enterotomies},
  journal = {Veterinary Surgery},
  year = {2024},
  doi = {10.1111/vsu.14059}
}
Kostenlos starten →