EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC 4.0

Biomechanical comparison of standard-of-care endoprosthesis limb-sparing technique to a gap group with stainless steel plates and no endoprostheses in the distal radial site of dogs

Josep Aisa iD, James W Johnson iD, Brandan G Wustefeld-Janssens iD

American Journal of Veterinary Research · 2025

DOI: 10.2460/ajvr.24.11.0364 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift American Journal of Veterinary Research, 2025. Verfasst von Josep Aisa und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida Gainesville, FL. Hauptthemen laut MEDLINE: Bone Plates, Limb Salvage, Forelimb. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare the biomechanical properties of standard-of-care limb salvage stainless steel plates with metal endoprosthesis constructs to constructs without endoprosthesis.

Methods

This was a cadaveric biomechanical study including 5 pairs of normal canine thoracic limbs randomly allocated into 2 groups: limbs with a second-generation, 11.5-mm Veterinary Orthopedic Implants stainless steel plate and a 122-mm stainless steel with endoprosthesis (SS-E) and limbs without endoprostheses or stainless steel with a gap (SS-G). Standard limb-spare surgery was performed and reconstructed with or without endoprostheses (ie, gap). Limbs were tested in axial loading until failure, and load-deformation curves were used to determine the biomechanical properties of the constructs, compared using a Wilcoxon matched-pairs signed-rank test. Failure modes were compared descriptively.

Results

Yield load (644 ± 523 N and 288 ± 153 N), yield energy absorbed (1,126 ± 1,695 N/mm and 239 ± 251 N/mm), and ultimate energy absorbed (39,732 ± 11,679 N/mm and 5,175 ± 878 N/mm) were significantly different between the SS-E and SS-G groups, respectively. Stiffness (360 ± 64 N/mm and 180 ± 50 N/mm) and ultimate load (3,385 ± 512 N and 747 ± 98 N) were not. The mode of failure varied between groups, with 2 SS-E constructs failing by humeral fracture and 3 by plate bending at the most distal radial or radiocarpal screw holes, whereas all SS-G constructs failed by plate bending midgap.

Conclusions

Limbs incorporating endoprosthesis were biomechanically superior to limbs reconstructed with a gap. Clinical Relevance Limbs reconstructed with locking 11.5-mm Veterinary Orthopedic Implants plates without endoprosthesis may fail at physiological forces during trot or run.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone PlatesLimb SalvageForelimbAnimalsDogsStainless SteelBiomechanical PhenomenaCadaver

Stichwörter der Autor:innen

biomechanical testingendoprosthesislimb spareosteosarcomaradius

Substanzen

Stainless Steel

Autor:innen und Institutionen

  • Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida Gainesville, FL.
  • Flint Animal Cancer Center, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, CO.
  • Department of Mechanical Engineering, Walter Scott Jr College of Engineering, Colorado State University, Fort Collins, CO.

ORCID-Profile: Josep Aisa, James W Johnson, Brandan G Wustefeld-Janssens

Zitieren

APA

Aisa, J., Johnson, J. W., & Wustefeld-Janssens, B. G. (2025). Biomechanical comparison of standard-of-care endoprosthesis limb-sparing technique to a gap group with stainless steel plates and no endoprostheses in the distal radial site of dogs. American Journal of Veterinary Research. https://doi.org/10.2460/ajvr.24.11.0364

Vancouver

Aisa J, Johnson JW, Wustefeld-Janssens BG. Biomechanical comparison of standard-of-care endoprosthesis limb-sparing technique to a gap group with stainless steel plates and no endoprostheses in the distal radial site of dogs. American Journal of Veterinary Research. 2025. doi:10.2460/ajvr.24.11.0364

BibTeX
@article{Aisa2025,
  author = {Aisa, Josep and Johnson, James W and Wustefeld-Janssens, Brandan G},
  title = {Biomechanical comparison of standard-of-care endoprosthesis limb-sparing technique to a gap group with stainless steel plates and no endoprostheses in the distal radial site of dogs},
  journal = {American Journal of Veterinary Research},
  year = {2025},
  doi = {10.2460/ajvr.24.11.0364}
}
Kostenlos starten →