EUVIMEDEUVIMED entdecken
Vergleichsstudie

An Ex Vivo Comparison of Stainless Steel Cables to a Non-metallic Polymer Cerclage Cable in an Equine Metacarpophalangeal Joint Arthrodesis Model

Lawrence I M Kadic iD, Chin-Chi Liu iD, Laura M Riggs

Veterinary and Comparative Orthopaedics and Traumatology · 01.11.2025 · 38 (06) · 302-307

DOI: 10.1055/a-2591-7825 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Veterinary and Comparative Orthopaedics and Traumatology, erschienen am 01.11.2025. Verfasst von Lawrence I M Kadic und 2 weiteren Autor:innen. Beteiligte Einrichtung: Large Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida, United States. Hauptthemen laut MEDLINE: Stainless Steel, Arthrodesis, Metacarpophalangeal Joint, Bone Wires. Die Arbeit nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of this study was to compare the monotonic tensile strength and fatigue strength of a stainless steel cable (SSC) compared to a human non-metallic polymer cable (NMPC) in an ex vivo metacarpophalangeal joint arthrodesis model lacking a dorsal plate application. An ex vivo experimental biomechanical equine cadaver limb study. Ten metacarpophalangeal joints were collected from five adult Thoroughbred horses, euthanatized for reasons unrelated to orthopaedic disease. Each pair of metacarpophalangeal joints was randomly instrumented with either a 1.7-mm SSC or a NMPC. Each construct was tested in cyclic loading followed by a single cycle to failure in axial compression. Displacement at a target load of 200 N over 500 cycles at 1 Hz was recorded prior to single-cycle to failure testing. In cyclic testing, the overall movement of the NMPC constructs was more than that of the SSC constructs (p < 0.0001). In single-cycle testing, the maximum load achieved at failure in the SSC constructs was higher compared to the NMPC constructs (p = 0.0002). The results of this study do not support the use of a NMPC as a palmar/plantar tension band for metacarpophalangeal joint arthrodesis in horses suffering from a suspensory breakdown injury, because the stability of the SSC constructs outweighs the potential benefits and ease of application of the NMPC. However, additional ex vivo studies should be conducted to compare both cable systems with dorsal plate application on the metacarpophalangeal joint.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Stainless SteelArthrodesisMetacarpophalangeal JointBone WiresAnimalsHorsesCadaverPolymersBiomechanical PhenomenaTensile StrengthMaterials Testing

Substanzen

Stainless SteelPolymers

Autor:innen und Institutionen

  • Large Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida, United States.
  • Office of Research and Graduate Education, School of Veterinary Medicine, Louisiana State University, Baton Rouge, Louisiana, United States.
  • Department of Veterinary Clinical Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge, Louisiana, United States.

ORCID-Profile: Lawrence I M Kadic, Chin-Chi Liu

Zitieren

APA

Kadic, L. I. M., Liu, C. C., & Riggs, L. M. (2025). An Ex Vivo Comparison of Stainless Steel Cables to a Non-metallic Polymer Cerclage Cable in an Equine Metacarpophalangeal Joint Arthrodesis Model. Veterinary and Comparative Orthopaedics and Traumatology, 38(06), 302-307. https://doi.org/10.1055/a-2591-7825

Vancouver

Kadic LIM, Liu CC, Riggs LM. An Ex Vivo Comparison of Stainless Steel Cables to a Non-metallic Polymer Cerclage Cable in an Equine Metacarpophalangeal Joint Arthrodesis Model. Veterinary and Comparative Orthopaedics and Traumatology. 2025;38(06):302-307. doi:10.1055/a-2591-7825

BibTeX
@article{Kadic2025,
  author = {Kadic, Lawrence I M and Liu, Chin-Chi and Riggs, Laura M},
  title = {An Ex Vivo Comparison of Stainless Steel Cables to a Non-metallic Polymer Cerclage Cable in an Equine Metacarpophalangeal Joint Arthrodesis Model},
  journal = {Veterinary and Comparative Orthopaedics and Traumatology},
  year = {2025},
  volume = {38},
  number = {06},
  pages = {302--307},
  doi = {10.1055/a-2591-7825}
}