Effects of Metal Implants on Computed Tomographic Attenuation Values in the Canine Antebrachium: A Cadaveric Study
Veterinary Radiology & Ultrasound · 2025
DOI: 10.1111/vru.70103 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Radiology & Ultrasound, 2025. Verfasst von Giulia Dalla Serra und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Imaging, School of Veterinary Medicine, University College Dublin, Dublin, Ireland. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Forelimb. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Computed tomography (CT) of postoperative orthopedic cases can yield valuable clinical information, especially when radiographic findings are equivocal. Image quality can be adversely affected by the presence of metallic implants. Several studies evaluating metal artifacts on CT have been published in humans, but studies involving veterinary patients are limited. This study aimed to assess attenuation value changes caused by metal artifacts on adjacent anatomical structures. This prospective cadaveric study included 20 Greyhound cadaver forelimbs. The limbs underwent CT before and after application of a 316L stainless steel plate and screws along the cranial surface of the radius. Attenuation values of the radial cortex, medulla, and caudal soft tissues were compared before and after implant placement. Five anatomical sites along the antebrachium were selected for comparison: (1) at the level of a non‐filled plate hole, (2) along the plate between 2 screws, (3) at the edge of the plate, and (4) 1 and (5) 3 cm proximal to the plate, respectively. The attenuation values between pre‐ and post‐implant images were significantly different in the radial medulla, cranial, and caudal cortices at Sites 2 and 3, and in the cranial radial cortex at Site 1. No significant differences were found in the antebrachial caudal soft tissues at any site, nor at any region at Sites 4 and 5. The presence of stainless steel implants significantly affects the attenuation values of adjacent cortical and medullary bone, which may lead to image interpretation errors.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostic Imaging, School of Veterinary Medicine, University College Dublin, Dublin, Ireland.
- Department of Small Animal Surgery, Section of Small Animal Clinical Studies, School of Veterinary Medicine, University College Dublin, Dublin, Ireland.
- School of Physics, University College Dublin, Dublin, Ireland.
ORCID-Profile: Giulia Dalla Serra
Zitieren
APA
Dalla Serra, G., Maurin, M. P., Skelly, C., Hernandez-Girón, I., & Hoey, S. (2025). Effects of Metal Implants on Computed Tomographic Attenuation Values in the Canine Antebrachium: A Cadaveric Study. Veterinary Radiology & Ultrasound. https://doi.org/10.1111/vru.70103
Vancouver
Dalla Serra G, Maurin MP, Skelly C, Hernandez-Girón I, Hoey S. Effects of Metal Implants on Computed Tomographic Attenuation Values in the Canine Antebrachium: A Cadaveric Study. Veterinary Radiology & Ultrasound. 2025. doi:10.1111/vru.70103
BibTeX
@article{DallaSerra2025,
author = {Dalla Serra, Giulia and Maurin, Marie-Pauline and Skelly, Cliona and Hernandez-Girón, Irene and Hoey, Séamus},
title = {Effects of Metal Implants on Computed Tomographic Attenuation Values in the Canine Antebrachium: A Cadaveric Study},
journal = {Veterinary Radiology & Ultrasound},
year = {2025},
doi = {10.1111/vru.70103}
}
EUVIMED