EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

K-wire is more damaging than standard or acrylic drill bits when evaluating torsional properties of rabbit (Oryctolagus cuniculi) femurs

Anna M Massie, Amy S Kapatkin, Tanya C Garcia, Denis J Marcellin-Little, David Sanchez-Migallon Guzman, Po-Yen Chou, Susan M Stover

American Journal of Veterinary Research · 2024

DOI: 10.2460/ajvr.24.01.0006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Veterinary Research, 2024. Verfasst von Anna M Massie und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences and Advanced Medicine, University of California-Davis, Philadelphia, PA. Hauptthemen laut MEDLINE: Femur, Bone Wires. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE The objective of this study is to compare drilling variables and torsional mechanical properties of rabbit femora after bicortical drilling with a 1.5-mm standard surgical drill bit, acrylic drill bit, and K-wire. SAMPLES 24 pairs of rabbit femora. METHODS After drilling under controlled axial displacement rate, each bone was biaxially loaded in compression followed by rapid external torsion to failure. Maximum axial thrust force, maximum drill torque, integral of force and displacement, change in temperature, maximum power spectral density of the torque signal, torque vibration, and torque and angle at the yield and failure points were collected. Pre- and postyield stiffness, yield and failure energies, and postyield energy were calculated. RESULTS The work required to drill through the cis- and transcortices (integral of force and displacement) was greater for the K-wire, followed by the acrylic and then standard drill bits, respectively. The K-wire demonstrated higher maximum torque than the drill bits at the ciscortex, and the force of drilling was significantly greater. The vibration data was greater with the acrylic and standard drill bits than the K-wire. There was no difference in torsional strength between drilling types. CLINICAL RELEVANCE Mechanical differences exist between different drill bits and K-wire and demonstrate that the K-wire is overall more damaging than the surgical drill bit.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FemurBone WiresAnimalsRabbitsBiomechanical PhenomenaTorsion, MechanicalTorque

Stichwörter der Autor:innen

biomechanicsdrill bitdrill holerabbit bonetorsional properties

Autor:innen und Institutionen

  • Department of Clinical Sciences and Advanced Medicine, University of California-Davis, Philadelphia, PA.
  • Department of Surgical and Radiological Sciences, University of California-Davis, Davis, CA.
  • JD Wheat Veterinary Orthopedic Research Laboratory, Davis, CA.
  • Department of Medicine and Epidemiology, University of California-Davis, Davis, CA.

Zitieren

APA

Massie, A. M., Kapatkin, A. S., Garcia, T. C., Marcellin-Little, D. J., Guzman, D. S., Chou, P. Y., & Stover, S. M. (2024). K-wire is more damaging than standard or acrylic drill bits when evaluating torsional properties of rabbit (Oryctolagus cuniculi) femurs. American Journal of Veterinary Research. https://doi.org/10.2460/ajvr.24.01.0006

Vancouver

Massie AM, Kapatkin AS, Garcia TC, Marcellin-Little DJ, Guzman DS, Chou PY, et al. K-wire is more damaging than standard or acrylic drill bits when evaluating torsional properties of rabbit (Oryctolagus cuniculi) femurs. American Journal of Veterinary Research. 2024. doi:10.2460/ajvr.24.01.0006

BibTeX
@article{Massie2024,
  author = {Massie, Anna M and Kapatkin, Amy S and Garcia, Tanya C and Marcellin-Little, Denis J and Guzman, David Sanchez-Migallon and Chou, Po-Yen and Stover, Susan M},
  title = {K-wire is more damaging than standard or acrylic drill bits when evaluating torsional properties of rabbit (Oryctolagus cuniculi) femurs},
  journal = {American Journal of Veterinary Research},
  year = {2024},
  doi = {10.2460/ajvr.24.01.0006}
}
Kostenlos starten →