Plating and double‐loop cerclage wiring improve the mechanical performance of the femoral stem after Zurich cementless total hip replacement in cats
Veterinary Surgery · 2026
DOI: 10.1111/vsu.70074 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Surgery, 2026. Verfasst von Clair Park und 4 weiteren Autor:innen. Beteiligte Einrichtung: Virginia-Maryland College of Veterinary Medicine, Blacksburg, Virginia, USA. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Bone Wires, Bone Plates, Femur. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objective
To compare the biomechanical performance of adjunctive locking plating and double‐loop cerclage wiring in feline femora implanted with Zurich cementless total hip replacement (THR) stems. Study design Cadaveric biomechanical study. Animals Paired femora ( n = 32) from 16 feline cadavers.
Methods
Two sequential studies were performed. First, femora implanted with Zurich cementless stems alone were compared with those stabilized by an adjunctive locking plate. Second, femora with locking plates were compared with those with cerclage wires. Constructs underwent cyclic axial and torsional loading followed by load‐to‐failure testing. Outcome measures included residual axial and torsional displacement, yield and ultimate forces and torques, energy absorption, and brittle failure frequency. Parameters were normalized to bone volume.
Results
The locking plate group demonstrated substantially reduced residual torsional displacement and a trend toward lower axial displacement compared with the stem‐only group. Yield and ultimate failure strength did not differ. The cerclage group exhibited 36% greater ultimate axial displacement, 76% greater energy absorption, and 32% greater torsional displacement than the locking plate group. Normalization accentuated these differences. Cerclage wire fixation was associated with a lower frequency of brittle failure.
Conclusion
Locking plates improved cyclic stability by reducing micromotion, while cerclage wires enhanced compliance and energy absorption under destructive loading. Neither method increased load to failure. Clinical significance Adjunctive plate or cerclage wire provided biomechanical advantages in femora implanted with Zurich cementless THR stems. Locking plates may support implant stability, whereas cerclage wiring improves energy dissipation under supraphysiologic loading. Adjunctive fixation strategies should be tailored to patient‐specific femoral morphology and fracture risk in feline THR.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Virginia-Maryland College of Veterinary Medicine, Blacksburg, Virginia, USA.
- JD Wheat Veterinary Orthopedic Research Laboratory, School of Veterinary Medicine, University of California-Davis, Davis, California, USA.
- KYON, Zurich, Switzerland.
ORCID-Profile: Denis J Marcellin-Little
Zitieren
APA
Park, C., Marcellin-Little, D. J., Garcia-Nolen, T., Bresina, S. J., & Lanz, O. I. (2026). Plating and double‐loop cerclage wiring improve the mechanical performance of the femoral stem after Zurich cementless total hip replacement in cats. Veterinary Surgery. https://doi.org/10.1111/vsu.70074
Vancouver
Park C, Marcellin-Little DJ, Garcia-Nolen T, Bresina SJ, Lanz OI. Plating and double‐loop cerclage wiring improve the mechanical performance of the femoral stem after Zurich cementless total hip replacement in cats. Veterinary Surgery. 2026. doi:10.1111/vsu.70074
BibTeX
@article{Park2026,
author = {Park, Clair and Marcellin-Little, Denis J and Garcia-Nolen, Tanya and Bresina, Stephen J and Lanz, Otto I},
title = {Plating and double‐loop cerclage wiring improve the mechanical performance of the femoral stem after Zurich cementless total hip replacement in cats},
journal = {Veterinary Surgery},
year = {2026},
doi = {10.1111/vsu.70074}
}
EUVIMED