EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Plating and double‐loop cerclage wiring improve the mechanical performance of the femoral stem after Zurich cementless total hip replacement in cats

Clair Park, Denis J Marcellin-Little iD, Tanya Garcia-Nolen, Stephen J Bresina, Otto I Lanz

Veterinary Surgery · 2026

DOI: 10.1111/vsu.70074 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Surgery, 2026. Verfasst von Clair Park und 4 weiteren Autor:innen. Beteiligte Einrichtung: Virginia-Maryland College of Veterinary Medicine, Blacksburg, Virginia, USA. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Bone Wires, Bone Plates, Femur. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare the biomechanical performance of adjunctive locking plating and double‐loop cerclage wiring in feline femora implanted with Zurich cementless total hip replacement (THR) stems. Study design Cadaveric biomechanical study. Animals Paired femora ( n = 32) from 16 feline cadavers.

Methods

Two sequential studies were performed. First, femora implanted with Zurich cementless stems alone were compared with those stabilized by an adjunctive locking plate. Second, femora with locking plates were compared with those with cerclage wires. Constructs underwent cyclic axial and torsional loading followed by load‐to‐failure testing. Outcome measures included residual axial and torsional displacement, yield and ultimate forces and torques, energy absorption, and brittle failure frequency. Parameters were normalized to bone volume.

Results

The locking plate group demonstrated substantially reduced residual torsional displacement and a trend toward lower axial displacement compared with the stem‐only group. Yield and ultimate failure strength did not differ. The cerclage group exhibited 36% greater ultimate axial displacement, 76% greater energy absorption, and 32% greater torsional displacement than the locking plate group. Normalization accentuated these differences. Cerclage wire fixation was associated with a lower frequency of brittle failure.

Conclusion

Locking plates improved cyclic stability by reducing micromotion, while cerclage wires enhanced compliance and energy absorption under destructive loading. Neither method increased load to failure. Clinical significance Adjunctive plate or cerclage wire provided biomechanical advantages in femora implanted with Zurich cementless THR stems. Locking plates may support implant stability, whereas cerclage wiring improves energy dissipation under supraphysiologic loading. Adjunctive fixation strategies should be tailored to patient‐specific femoral morphology and fracture risk in feline THR.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipBone WiresBone PlatesFemurHip ProsthesisAnimalsCatsBiomechanical PhenomenaCadaver

Autor:innen und Institutionen

  • Virginia-Maryland College of Veterinary Medicine, Blacksburg, Virginia, USA.
  • JD Wheat Veterinary Orthopedic Research Laboratory, School of Veterinary Medicine, University of California-Davis, Davis, California, USA.
  • KYON, Zurich, Switzerland.

ORCID-Profile: Denis J Marcellin-Little

Zitieren

APA

Park, C., Marcellin-Little, D. J., Garcia-Nolen, T., Bresina, S. J., & Lanz, O. I. (2026). Plating and double‐loop cerclage wiring improve the mechanical performance of the femoral stem after Zurich cementless total hip replacement in cats. Veterinary Surgery. https://doi.org/10.1111/vsu.70074

Vancouver

Park C, Marcellin-Little DJ, Garcia-Nolen T, Bresina SJ, Lanz OI. Plating and double‐loop cerclage wiring improve the mechanical performance of the femoral stem after Zurich cementless total hip replacement in cats. Veterinary Surgery. 2026. doi:10.1111/vsu.70074

BibTeX
@article{Park2026,
  author = {Park, Clair and Marcellin-Little, Denis J and Garcia-Nolen, Tanya and Bresina, Stephen J and Lanz, Otto I},
  title = {Plating and double‐loop cerclage wiring improve the mechanical performance of the femoral stem after Zurich cementless total hip replacement in cats},
  journal = {Veterinary Surgery},
  year = {2026},
  doi = {10.1111/vsu.70074}
}
Kostenlos starten →