EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Biomechanical comparison of cemented versus cementless fixation in intraoperative femoral fractures during total hip arthroplasty

Ryunosuke Watanabe, Tomofumi Nishino, Tomohiro Yoshizawa, Fumi Hirose, Shota Yasunaga, Koshiro Shimasaki, Hajime Mishima

Archives of Orthopaedic and Trauma Surgery · 2025

DOI: 10.1007/s00402-025-05987-6 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2025. Verfasst von Ryunosuke Watanabe und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Japan. ryuwatanabe@tsukuba-seikei.jp. Hauptthemen laut MEDLINE: Bone Cements, Femoral Fractures, Fracture Fixation, Internal, Femur. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Intraoperative periprosthetic femoral fractures (IPFF) are serious complications of total hip arthroplasty (THA) that occur more frequently with cementless stems than with cemented stems. Although cerclage wiring is commonly used to stabilize IPFFs, the biomechanical effects of subsequent stem fixation methods remain unclear. This study aimed to compare the biomechanical stability of cemented and cementless stems following cerclage wire fixation in an experimental IPFF model. Materials and methods Six fourth-generation composite femurs with simulated Vancouver A2-type fractures were stabilized using a single 1.8 mm cerclage wire. Identical stem designs of polished cemented stems and fully hydroxyapatite-coated cementless stems were implanted in three specimens of each group. After applying a vertical axial load of 2000 N, an additional 40° of internal rotation was imposed. The primary outcome was the maximum torque at the time of fracture. Secondary outcomes included the maximum internal rotation angle, construct stiffness (calculated from force-displacement curves above 1500 N), and peak strain at three positions on the cerclage wire, measured using strain gauges.

Results

The maximum torque was significantly higher in the cemented group compared to the cementless group (160.8 ± 24.9 vs. 89.1 ± 18.0 N·m, p = 0.016). Although the differences in stiffness and internal rotation angle were not statistically significant, both trended higher in the cemented group. The peak strain was consistently lower in the cemented group, with a significant difference at the medial side of the fracture line ( p = 0.011, Cohen’s d = − 3.64).

Conclusions

Cemented stems demonstrated superior biomechanical stability following cerclage wire fixation in the IPFF model, likely because of improved stress distribution via the cement mantle. Therefore, cemented fixation may be a favorable option for managing IPFF during THA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone CementsFemoral FracturesFracture Fixation, InternalFemurPeriprosthetic FracturesModels, AnatomicHumansBiomechanical PhenomenaArthroplasty, Replacement, HipIntraoperative ComplicationsTorqueHip ProsthesisBone WiresTreatment Outcome

Stichwörter der Autor:innen

Biomechanical testingCemented stemCementless stemCerclage wiringIntraoperative periprosthetic femoral fracturesTotal hip arthroplasty

Substanzen

Bone Cements

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Japan. ryuwatanabe@tsukuba-seikei.jp.
  • Department of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Japan.

Zitieren

APA

Watanabe, R., Nishino, T., Yoshizawa, T., Hirose, F., Yasunaga, S., Shimasaki, K., & Mishima, H. (2025). Biomechanical comparison of cemented versus cementless fixation in intraoperative femoral fractures during total hip arthroplasty. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-025-05987-6

Vancouver

Watanabe R, Nishino T, Yoshizawa T, Hirose F, Yasunaga S, Shimasaki K, et al. Biomechanical comparison of cemented versus cementless fixation in intraoperative femoral fractures during total hip arthroplasty. Archives of Orthopaedic and Trauma Surgery. 2025. doi:10.1007/s00402-025-05987-6

BibTeX
@article{Watanabe2025,
  author = {Watanabe, Ryunosuke and Nishino, Tomofumi and Yoshizawa, Tomohiro and Hirose, Fumi and Yasunaga, Shota and Shimasaki, Koshiro and Mishima, Hajime},
  title = {Biomechanical comparison of cemented versus cementless fixation in intraoperative femoral fractures during total hip arthroplasty},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2025},
  doi = {10.1007/s00402-025-05987-6}
}
Kostenlos starten →