Assessing Pre-Analytical Errors in Routine Hematology and Hemostatic Specimens: A Six-Sigma and Fishbone Approach
INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY · 10.11.2026 · 33 (1) · 1-5
DOI: 10.24293/ijcpml.v33i1.2670 ↗Kurz gefasst
Fachartikel in der Zeitschrift INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY, online erschienen am 10.11.2026. Verfasst von Farrawina Eka Putri Setyawan und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).
Abstract (Originalsprache)
Laboratory results are essential for medical decision-making, with pre-analytical errors being the most common cause of laboratory inaccuracies. This study aimed to assess pre-analytical errors in routine hematology and hemostatic function tests using the Six Sigma method and Root Cause Analysis (RCA) tool, specifically the Fishbone Diagram. A semi-quantitative descriptive study was conducted at the Clinical Pathology Laboratory, Dr. Soetomo General Academic Hospital, from December 2024 to February 2025. The total sampling method was used to evaluate 3,553 specimens, consisting of 1,941 hematology and 1,612 hemostatic function tests. Pre-analytical errors were analyzed using the Defects Per Million Opportunities (DPMO) method and converted into sigma values, while the Fishbone Diagram was used to identify contributing factors. A total of 40 pre-analytical errors were found. The most frequent error in hematology tests was clotted specimens (70%), whereas insufficient specimens were most common in hemostatic function tests (41%). Sigma values ranged from 4.5 to 5.3, with an overall sigma value of 4.0, indicating good but improvable performance. The Fishbone Diagram identified human error, improper sample handling, and procedural inconsistencies as key contributing factors. Addressing pre-analytical errors requires improved phlebotomy training, strict adherence to standardized protocols, and real-time error monitoring. Implementing Six Sigma and Fishbone Diagram analysis can significantly reduce errors, improve laboratory quality, and enhance patient safety.
Zitieren
APA
Setyawan, F. E. P., Wardhani, P., & Fuadi, M. R. (2026). Assessing Pre-Analytical Errors in Routine Hematology and Hemostatic Specimens: A Six-Sigma and Fishbone Approach. INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY, 33(1), 1-5. https://doi.org/10.24293/ijcpml.v33i1.2670
Vancouver
Setyawan FEP, Wardhani P, Fuadi MR. Assessing Pre-Analytical Errors in Routine Hematology and Hemostatic Specimens: A Six-Sigma and Fishbone Approach. INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY. 2026;33(1):1-5. doi:10.24293/ijcpml.v33i1.2670
BibTeX
@article{Setyawan2026,
author = {Setyawan, Farrawina Eka Putri and Wardhani, Puspa and Fuadi, Muhammad Robiul},
title = {Assessing Pre-Analytical Errors in Routine Hematology and Hemostatic Specimens: A Six-Sigma and Fishbone Approach},
journal = {INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY},
year = {2026},
volume = {33},
number = {1},
pages = {1--5},
doi = {10.24293/ijcpml.v33i1.2670}
}