EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Advancing endodontic imaging: a high-resolution comparison between CBCT and micro-CT in the danger zone

Gabriel de Toledo Telles-Araujo iD, Raimundo Sales de Oliveira Neto iD, Mariana Quirino Silveira Soares iD, Heitor Marques Honório iD, Viviane Almeida Sarmento iD, Marco Antônio Hungaro Duarte iD, Izabel Regina Fischer Rubira-Bullen iD

Biomaterial Investigations in Dentistry · 05.08.2026 · 13 · 638-646

DOI: 10.2340/biid.v13.46618 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomaterial Investigations in Dentistry, online erschienen am 05.08.2026. Verfasst von Gabriel de Toledo Telles-Araujo und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, Federal University of Bahia, Salvador, Brazil. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This study evaluated the accuracy of cone-beam computed tomography (CBCT) protocols for measuring submillimetric dentin thickness in the danger zone (DZ) of mandibular molars, using micro-computed tomography (micro-CT) as the reference standard. Materials and methods: Fifty-one extracted mandibular molars were scanned using micro-CT and two CBCT devices under different acquisition protocols (Standard, High Fidelity, High Resolution [HIRE], and Imaging System [i-CAT]). After three-dimensional image registration, dentin thickness in the DZ, located 2 mm below the furcation, was measured in both mesial canals.

Results

All CBCT protocols significantly underestimated dentin thickness compared with micro-CT (p < 0.05), with discrepancies ranging from 4.5 to 8.6%. Underestimation was more pronounced in the mesiolingual canal. The HIRE protocol (0.125 mm voxel size) showed the smallest discrepancy, whereas the i-CAT protocol showed the largest.Conclusion(s): CBCT systematically underestimates dentin thickness in the DZ and is not metrically equivalent to micro-CT for submillimetric measurements. Measurement accuracy is influenced by acquisition parameters and cannot be explained by voxel size alone.

Schlagwörter

Stichwörter der Autor:innen

Cone-beam computed tomographydanger zoneendodonticsmicro-computed tomographyroot canal

Autor:innen und Institutionen

  • School of Medicine, Federal University of Bahia, Salvador, Brazil.
  • Department of Operative Dentistry, Endodontics, and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil.
  • Oral Radiology Division, São Leopoldo Mandic Research Institute, Campinas, Brazil.
  • Department of Pediatric Dentistry, Orthodontics and Public Health, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil.
  • School of Dentistry, Federal University of Bahia, State University of Feira de Santana, Bahia, Brazil.
  • Department of Surgery, Stomatology, Pathology and Radiology, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil.

ORCID-Profile: Gabriel de Toledo Telles-Araujo, Raimundo Sales de Oliveira Neto, Mariana Quirino Silveira Soares, Heitor Marques Honório, Viviane Almeida Sarmento, Marco Antônio Hungaro Duarte, Izabel Regina Fischer Rubira-Bullen

Zitieren

APA

Telles-Araujo, G. T., de Oliveira Neto, R. S., Soares, M. Q. S., Honório, H. M., Sarmento, V. A., Duarte, M. A. H., & Rubira-Bullen, I. R. F. (2026). Advancing endodontic imaging: a high-resolution comparison between CBCT and micro-CT in the danger zone. Biomaterial Investigations in Dentistry, 13, 638-646. https://doi.org/10.2340/biid.v13.46618

Vancouver

Telles-Araujo GT, de Oliveira Neto RS, Soares MQS, Honório HM, Sarmento VA, Duarte MAH, et al. Advancing endodontic imaging: a high-resolution comparison between CBCT and micro-CT in the danger zone. Biomaterial Investigations in Dentistry. 2026;13:638-646. doi:10.2340/biid.v13.46618

BibTeX
@article{TellesAraujo2026,
  author = {Telles-Araujo, Gabriel de Toledo and de Oliveira Neto, Raimundo Sales and Soares, Mariana Quirino Silveira and Honório, Heitor Marques and Sarmento, Viviane Almeida and Duarte, Marco Antônio Hungaro and Rubira-Bullen, Izabel Regina Fischer},
  title = {Advancing endodontic imaging: a high-resolution comparison between CBCT and micro-CT in the danger zone},
  journal = {Biomaterial Investigations in Dentistry},
  year = {2026},
  volume = {13},
  pages = {638--646},
  doi = {10.2340/biid.v13.46618}
}
Kostenlos starten →