Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study

Kheya Patel, Feng-Ming Wang, Mehrnaz Tahmasbi, Fabricio Teixeira, Madhu Nair, Poorya Jalali

Journal of Endodontics · 2026-03 · 52 (3) · 442-450

DOI: 10.1016/j.joen.2025.11.016 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Endodontics, 2026-03. Verfasst von Kheya Patel und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endodontics, Texas A&M College of Dentistry, Dallas, Texas. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, X-Ray Microtomography, Dental Pulp Cavity. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Cone-beam computed tomography (CBCT) is widely used to assess root canal morphology, yet practical size thresholds for canal visibility have not been established. This study determined the relationship between canal diameter and the probability of confident detection on high-resolution CBCT using micro-computed tomography (micro-CT) for reference. METHODS: Sixty-one extracted human teeth (251 canal cross-sections, including 9 with no visible lumen) were imaged with both imaging modalities. True canal diameters measured on micro-CT were spatially matched to corresponding CBCT cross-sections using anatomical landmarks. Three calibrated observers rated canal visibility on a 5-point scale; scores ≥4 indicated confident detection. Interobserver reliability was quantified using Krippendorff's α and quadratic-weighted κ. A binomial logistic regression modeled detection probability as a function of diameter. Receiver operating characteristic (ROC) analysis assessed overall discriminative accuracy. RESULTS: Interobserver agreement was excellent (α = 0.87; κ = 0.78-0.91). The probability of confident canal detection increased sharply with canal diameter. Model estimates indicated a 70% probability (D70) at a canal diameter of approximately 265 μm, an 80% probability (D80) at 299 μm, and a 90% probability (D90) at 350 μm. ROC analysis demonstrated excellent discriminative performance (area under the curve = 0.89), confirming strong accuracy of CBCT visibility scores for identifying canals present on micro-CT. CONCLUSIONS: On 80-μm-voxel CBCT, consistent canal visibility emerges at approximately 300 μm. Canals measuring 200 to 300 μm are often visible, whereas those smaller than about 200 μm are frequently missed. The detection thresholds identified in this study may help clinicians anticipate when a canal is likely still patent but radiographically undetectable.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyX-Ray MicrotomographyDental Pulp CavityHumansReproducibility of ResultsObserver Variation

Autor:innen und Institutionen

  • Department of Endodontics, Texas A&M College of Dentistry, Dallas, Texas.
  • Department of Endodontics, Texas A&M College of Dentistry, Dallas, Texas. Electronic address: jalali@tamu.edu.

Zitieren

APA

Patel, K., Wang, F. M., Tahmasbi, M., Teixeira, F., Nair, M., & Jalali, P. (2026). Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study. Journal of Endodontics, 52(3), 442-450. https://doi.org/10.1016/j.joen.2025.11.016

Vancouver

Patel K, Wang FM, Tahmasbi M, Teixeira F, Nair M, Jalali P. Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study. Journal of Endodontics. 2026;52(3):442-450. doi:10.1016/j.joen.2025.11.016

BibTeX
@article{Patel2026,
  author = {Patel, Kheya and Wang, Feng-Ming and Tahmasbi, Mehrnaz and Teixeira, Fabricio and Nair, Madhu and Jalali, Poorya},
  title = {Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study},
  journal = {Journal of Endodontics},
  year = {2026},
  volume = {52},
  number = {3},
  pages = {442--450},
  doi = {10.1016/j.joen.2025.11.016}
}
Kostenlos starten →