Elemental composition, corrosion resistance and mechanical properties of computer-aided design and computer-aided manufacturing fixed retainers versus conventional fixed retainers

Yasuhiro Namura, Helen Pullisaar, Heidi Vanessa Holm, Morten Syverud, Aida Mulic, Vaska Vandevska-Radunovic

Journal of Oral Science · 2024

DOI: 10.2334/josnusd.23-0303 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Oral Science, 2024. Verfasst von Yasuhiro Namura und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Nihon University School of Dentistry. Hauptthemen laut MEDLINE: Nickel, Orthodontic Retainers. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: Nihon University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To investigate the elemental composition, corrosion resistance, and mechanical properties of computer-aided design and computer-aided manufacturing (CAD-CAM) retainers versus conventional fixed retainers (FRs). METHODS: Eight different retainer wires were investigated. Energy dispersive X-ray spectroscopy was used to determine the elemental composition. Leakage was analysed according to ISO 10271:2020 guidelines. Hardness was tested using the Vickers method with a load of 0.3 kg. The tensile force and tensile strength were evaluated. Multiple comparisons among wires of hardness, tensile force, and strength were conducted using the Welch t-test, with Bonferroni correction. RESULTS: Nickel was present in all wires. The CAD-CAM-FR wire, which contained more nickel than the other wires, had no measurable leakage. The gold-plated wires had the highest total leakage, but did not exceed the ISO standard limit. The hardness of the stainless-steel twisted wires was the highest and that of the CAD-CAM-FR wire was the lowest. The tensile strength of the CAD-CAM-FR wire was significantly lower than that of the other wires and similar to the other twisted-wire retainers. CONCLUSION: The CAD-CAM-FR wire is likely to have high corrosion resistance and flexibility due to its low hardness.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NickelOrthodontic RetainersCorrosionOrthodontic WiresOrthodontic Appliances, FixedComputer-Aided Design

Stichwörter der Autor:innen

corrosion resistancehardnessorthodontic retainerorthodontic wiretensile strength

Substanzen

Nickel

Autor:innen und Institutionen

  • Department of Orthodontics, Nihon University School of Dentistry.
  • Section of Orthodontics, Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo.
  • Nordic Institute of Dental Materials.

Förderung

  • Nihon University

Zitieren

APA

Namura, Y., Pullisaar, H., Holm, H. V., Syverud, M., Mulic, A., & Vandevska-Radunovic, V. (2024). Elemental composition, corrosion resistance and mechanical properties of computer-aided design and computer-aided manufacturing fixed retainers versus conventional fixed retainers. Journal of Oral Science. https://doi.org/10.2334/josnusd.23-0303

Vancouver

Namura Y, Pullisaar H, Holm HV, Syverud M, Mulic A, Vandevska-Radunovic V. Elemental composition, corrosion resistance and mechanical properties of computer-aided design and computer-aided manufacturing fixed retainers versus conventional fixed retainers. Journal of Oral Science. 2024. doi:10.2334/josnusd.23-0303

BibTeX
@article{Namura2024,
  author = {Namura, Yasuhiro and Pullisaar, Helen and Holm, Heidi Vanessa and Syverud, Morten and Mulic, Aida and Vandevska-Radunovic, Vaska},
  title = {Elemental composition, corrosion resistance and mechanical properties of computer-aided design and computer-aided manufacturing fixed retainers versus conventional fixed retainers},
  journal = {Journal of Oral Science},
  year = {2024},
  doi = {10.2334/josnusd.23-0303}
}
Kostenlos starten →