Reproducibility and accuracy of machine bent 3- and 6-stranded twistflex lingual fixed retainers—An in-vitro-study
Journal of the World Federation of Orthodontists · 2025
DOI: 10.1016/j.ejwf.2025.05.008 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the World Federation of Orthodontists, 2025. Verfasst von Katharina Klaus und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Justus Liebig University Giessen, Giessen, Germany. Electronic address: katharina.klaus@dentist.med.uni-giessen.de. Hauptthemen laut MEDLINE: Computer-Aided Design, Orthodontic Retainers, Orthodontic Appliance Design. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: German Society of Orthodontics.
Abstract (Originalsprache)
BACKGROUND: The present study aimed to evaluate the precision with which a retainer bending machine can produce the designed CAD/CAM retainer. METHODS: Canine-to-canine retainers were digitally designed and fabricated ten times each on 20 debonding casts (10 upper, 10 lower) using the Bender II (YOAT Corp., Lynnwood, WA) with either 3- or 6-stranded twistflex wire. A master retainer for each model was created from the CAD/CAM coordinates and saved as a standard tessellation language (STL) file. All bent retainers were subsequently digitized using a laboratory scanner and superimposed with the master retainer (best-fit). Deviations between the machine-bent and master retainers were measured in millimeters across transversal, sagittal, and vertical dimensions. Statistical analysis was performed using a mixed linear model with fixed factors (jaw, wire type, number of retainers) and the number of casts as a random factor. RESULTS: For the entire sample, mean deviations ± standard deviation between master and bent retainers were 0.22 mm ± 0.64 in the transverse, -0.01 mm ± 0.33 in the sagittal, and 0.48 mm ± 0.23 in the vertical dimension. Lower retainers were found to be significantly more precise than upper retainers across all dimensions (transverse: P < 0.001; sagittal: P < 0.05; vertical: P < 0.001). Additionally, 3-stranded twistflex retainers demonstrated significantly greater accuracy compared to 6-stranded wires (transverse: P < 0.05; sagittal: P < 0.05; vertical: P < 0.001). CONCLUSIONS: The deviations in accuracy between the CAD/CAM planned retainer design and the machine-bent retainers could be clinically relevant, particularly for upper retainers in the transverse and vertical dimensions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthodontics, Justus Liebig University Giessen, Giessen, Germany. Electronic address: katharina.klaus@dentist.med.uni-giessen.de.
- Private Orthodontic Practice Green, Lutteroth and colleagues, Oldenburg, Germany.
- Department of Orthodontics, Justus Liebig University Giessen, Giessen, Germany.
Förderung
- German Society of Orthodontics
Zitieren
APA
Klaus, K., Pollmeier, J. D., & Ruf, S. (2025). Reproducibility and accuracy of machine bent 3- and 6-stranded twistflex lingual fixed retainers—An in-vitro-study. Journal of the World Federation of Orthodontists. https://doi.org/10.1016/j.ejwf.2025.05.008
Vancouver
Klaus K, Pollmeier JD, Ruf S. Reproducibility and accuracy of machine bent 3- and 6-stranded twistflex lingual fixed retainers—An in-vitro-study. Journal of the World Federation of Orthodontists. 2025. doi:10.1016/j.ejwf.2025.05.008
BibTeX
@article{Klaus2025,
author = {Klaus, Katharina and Pollmeier, Jan D and Ruf, Sabine},
title = {Reproducibility and accuracy of machine bent 3- and 6-stranded twistflex lingual fixed retainers—An in-vitro-study},
journal = {Journal of the World Federation of Orthodontists},
year = {2025},
doi = {10.1016/j.ejwf.2025.05.008}
}
EUVIMED