The corrosion products of proprietary and generic orthodontic fixed lingual retainers and their in-vitro cytotoxicity

Nessa A Finlay, Lam Cheng, Elizabeth Kelly, Peter Petocz, Narayan Gandedkar, Mehmet Ali Darendeliler, Oyku Dalci

The Angle Orthodontist · 2024

DOI: 10.2319/112823-788.1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Angle Orthodontist, 2024. Verfasst von Nessa A Finlay und 6 weiteren Autor:innen. Hauptthemen laut MEDLINE: Orthodontic Retainers, Fibroblasts, Materials Testing. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To assess the corrosion products and cytotoxicity of generic and proprietary fixed lingual retainers (FLRs). Materials and Methods Seven FLRs were investigated. Wires were submersed in solution for 34 days, at 37°C, under constant agitation. A proportion of this solution was analyzed to determine the concentration of metallic ions leaching off the wires. The remainder was diluted to 5%, 10% and 20% followed by exposure to human gingival fibroblasts and analysis of cytotoxicity of the wires.

Results

Three wires (Dentaflex, Universal, and AZDent) released excessive concentrations of lead, two wires (MeshMark and Orthoflex) released excessive concentrations of nickel, and one wire (Universal) released excessive concentrations of molybdenum into solution. No statistically significant difference was found between the wires analyzed ( P = .24). Slight cytotoxicity was noted in only one wire (Dentaflex) at a 20% dilution of eluent. This was also the wire which released the highest concentration of lead into solution. All other wires, at all concentrations, were deemed noncytotoxic, but five samples overall were deemed statistically significant ( P < .0024). A statistically significant difference existed between wires ( P = .013) and concentrations analyzed ( P < .001).

Conclusions

Metals were released in differing quantities from all wires, with some elemental concentrations measuring more than that deemed acceptable in drinking water in Australia. A trend toward increased cell viability across samples was found with only one demonstrating cytotoxicity. There was no indication that generic FLRs were more or less biocompatible than their proprietary counterparts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Orthodontic RetainersFibroblastsMaterials TestingHumansCorrosionGingivaOrthodontic WiresMolybdenumNickelCell SurvivalLeadCells, CulturedIn Vitro Techniques

Stichwörter der Autor:innen

CorrosionCytotoxicityFixed lingual retainerOrthodonticsRetainers

Substanzen

MolybdenumNickelLead

Zitieren

APA

Finlay, N. A., Cheng, L., Kelly, E., Petocz, P., Gandedkar, N., Darendeliler, M. A., & Dalci, O. (2024). The corrosion products of proprietary and generic orthodontic fixed lingual retainers and their in-vitro cytotoxicity. The Angle Orthodontist. https://doi.org/10.2319/112823-788.1

Vancouver

Finlay NA, Cheng L, Kelly E, Petocz P, Gandedkar N, Darendeliler MA, et al. The corrosion products of proprietary and generic orthodontic fixed lingual retainers and their in-vitro cytotoxicity. The Angle Orthodontist. 2024. doi:10.2319/112823-788.1

BibTeX
@article{Finlay2024,
  author = {Finlay, Nessa A and Cheng, Lam and Kelly, Elizabeth and Petocz, Peter and Gandedkar, Narayan and Darendeliler, Mehmet Ali and Dalci, Oyku},
  title = {The corrosion products of proprietary and generic orthodontic fixed lingual retainers and their in-vitro cytotoxicity},
  journal = {The Angle Orthodontist},
  year = {2024},
  doi = {10.2319/112823-788.1}
}
Kostenlos starten →