Assessment of different direct printed aligner resins for leaching of urethane dimethacrylate: an in vivo study
The Angle Orthodontist · 2026-11 · 96 (6) · 692-699
DOI: 10.2319/092225-788.1 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Angle Orthodontist, 2026-11. Verfasst von Aswathi Selvaraj und 5 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objectives
To evaluate the release of urethane dimethacrylate (UDMA) from the direct printed aligners using Tera Harz TC-85 resin (Graphy, Seoul, Korea) and Clear A resin (Senertek, Türkiye) in saliva samples at different time intervals. Materials and Methods This prospective quasiexperimental study included 2 groups: Group A Tera Harz TC-85 (Graphy, Seoul, Korea) and Group B Clear A resin (Senertek, Izmir, Türkiye), each with 13 participants. Patients wore aligners for more than 20 hours a day for 14 days. Whole saliva samples were obtained at several time intervals: T0 before aligners were inserted and T1, T2, and T3 after 24 hours, 7 days, and 14 days of usage, respectively. High-performance liquid chromatography was used to analyze the samples, and the average results were computed.
Results
Results showed significant variations in UDMA leaching between groups A and B at all postintervention periods. Group B had a significantly greater mean UDMA release than Group A at T1, T2, and T3. Intragroup analysis revealed time-dependent increases in UDMA release in both groups.
Conclusions
The findings revealed significant differences in UDMA release rates between the two materials, with Tera Harz TC-85 consistently showing lower levels of leaching than Clear A resin over the 14-day study period. Tera Harz TC-85 has superior performance in minimizing UDMA leaching, while both materials maintained acceptable profiles under the study conditions.
Schlagwörter
Stichwörter der Autor:innen
Zitieren
APA
Selvaraj, A., Prabhu, D., Krishnan, B., Tm, P., Krishnakumaran, M., & Kumar, M. (2026). Assessment of different direct printed aligner resins for leaching of urethane dimethacrylate: an in vivo study. The Angle Orthodontist, 96(6), 692-699. https://doi.org/10.2319/092225-788.1
Vancouver
Selvaraj A, Prabhu D, Krishnan B, Tm P, Krishnakumaran M, Kumar M. Assessment of different direct printed aligner resins for leaching of urethane dimethacrylate: an in vivo study. The Angle Orthodontist. 2026;96(6):692-699. doi:10.2319/092225-788.1
BibTeX
@article{Selvaraj2026,
author = {Selvaraj, Aswathi and Prabhu, Deepak and Krishnan, Balaji and Tm, Parameswaran and Krishnakumaran, Mahalakshmi and Kumar, Mohan},
title = {Assessment of different direct printed aligner resins for leaching of urethane dimethacrylate: an in vivo study},
journal = {The Angle Orthodontist},
year = {2026},
volume = {96},
number = {6},
pages = {692--699},
doi = {10.2319/092225-788.1}
}