EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Impact of ct tube voltage and anode current on pet/ct image quality a NEMA IQ Phantom Study

Milana Cavlin, Luka Lezaic, Sebastijan Rep

Nuclear Technology and Radiation Protection · 2026 · 41 (2) · 152-158

DOI: 10.2298/ntrp2602152c ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuclear Technology and Radiation Protection, 2026. Verfasst von Milana Cavlin und 2 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Positron emission tomography/computer tomography is a crucial modality for the quantification of metabolic activity and anatomical structure. Reducing radiation dose, especially in repeated imaging, remains a significant challenge. This study focuses on optimizing computer tomography parameters to reduce dose, while maintaining image quality. The aim of this research was to determine the impact of varying computer tomography tube voltage and anode current, on the quantification of standardized uptake value, contrast-to-noise ratio, and radiation exposure (volume CT dose index, dose-length product). A NEMA IQ body phantom was scanned using various combinations of tube voltage and anode current. Standardized up-take value, contrast-to-noise ratio, volume CT dose index and dose-length product, were evaluated from the different scans. The obtained results were statistically assessed. Reducing tube voltage and anode current did not significantly affect standardized uptake value accuracy but, reduced radiation dose. Image quality (contrast-to-noise ratio) remained diagnostically acceptable, supporting the potential for optimization without compromising accuracy. Optimization of computer tomography parameters (tube voltage, anode current) is feasible and beneficial in clinical practice, as it reduces patient radiation burden while maintaining image quality and standardized uptake value accuracy.

Zitieren

APA

Cavlin, M., Lezaic, L., & Rep, S. (2026). Impact of ct tube voltage and anode current on pet/ct image quality a NEMA IQ Phantom Study. Nuclear Technology and Radiation Protection, 41(2), 152-158. https://doi.org/10.2298/ntrp2602152c

Vancouver

Cavlin M, Lezaic L, Rep S. Impact of ct tube voltage and anode current on pet/ct image quality a NEMA IQ Phantom Study. Nuclear Technology and Radiation Protection. 2026;41(2):152-158. doi:10.2298/ntrp2602152c

BibTeX
@article{Cavlin2026,
  author = {Cavlin, Milana and Lezaic, Luka and Rep, Sebastijan},
  title = {Impact of ct tube voltage and anode current on pet/ct image quality a NEMA IQ Phantom Study},
  journal = {Nuclear Technology and Radiation Protection},
  year = {2026},
  volume = {41},
  number = {2},
  pages = {152--158},
  doi = {10.2298/ntrp2602152c}
}
Kostenlos starten →