EUVIMEDEUVIMED entdecken
Crossref

The New CMS Measure of Excessive Radiation Dose or Inadequate Image Quality in CT: Issues and Ambiguities—Perspectives From an AAPM-Commissioned Panel

Jered R Wells, Olav Christianson, Dustin A Gress, Eric Gingold, Jurgen Jacobs, Kirsten Boedeker, Juan Carlos Ramirez-Giraldo, Lifeng Yu, Michael McNitt-Gray, Ehsan Samei

American Journal of Roentgenology · 2025-05 · 224 (5)

DOI: 10.2214/ajr.24.32458 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Roentgenology, 2025-05. Verfasst von Jered R Wells und 9 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Imaging Physicians Group, Duke Health, 2424 Erwin Rd, Hock Plaza, Ste 302, Durham, NC 27705. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiation Dosage, Quality Assurance, Health Care. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

CMS has adopted a new CT quality measure seeking to discourage excessive radiation dose while preserving image quality. The measure score is expressed as the percentage of qualifying studies that exceed predetermined thresholds, indicating inadequate image quality (based on image noise) or excessive radiation dose. The measure has been incorporated into the major CMS quality-based payment programs, impacting hospitals and clinician payments; measure reporting began in January 2025. After measure development, practitioners identified a spectrum of concerns and impediments, prompting the American Association of Physicists in Medicine to convene a multidisciplinary expert panel to provide further guidance. The panel identified 20 issues and ambiguities in the measure specifications, stemming from metrology concerns, unconventional terminology, and inconsistencies with practice standards or norms; these issues relate to themes of applicability, categories and metrics, informatics, performance expectations, and meta considerations. In this article, the panel presents these issues and ambiguities with associated recommendations to promote the measure's intentions. These recommendations include greater data access (e.g., to the measure's source data and to reporting elements for audit support) and a more holistic treatment of image quality. The panel ultimately urges a shift toward open-source, open-access, consensus-based, and community-owned strategies to ensure CT quality and safety.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedRadiation DosageQuality Assurance, Health CareHumansUnited StatesCenters for Medicare and Medicaid Services, U.S.Radiation Protection

Stichwörter der Autor:innen

CMSCTHIPPSHOPPSIQRMIPSMPFSOQReCQMimage qualitymetrologyradiation dose

Autor:innen und Institutionen

  • Clinical Imaging Physicians Group, Duke Health, 2424 Erwin Rd, Hock Plaza, Ste 302, Durham, NC 27705.
  • Imalogix, Bryn Mawr, PA.
  • American College of Radiology, Reston, VA.
  • Department of Health Administration and Policy, College of Public Health, George Mason University, Fairfax, VA.
  • Department of Radiology, Thomas Jefferson University, Philadelphia, PA.
  • Qaelum NV, Leuven, Belgium.

Zitieren

APA

Wells, J. R., Christianson, O., Gress, D. A., Gingold, E., Jacobs, J., Boedeker, K., Ramirez-Giraldo, J. C., Yu, L., McNitt-Gray, M., & Samei, E. (2025). The New CMS Measure of Excessive Radiation Dose or Inadequate Image Quality in CT: Issues and Ambiguities—Perspectives From an AAPM-Commissioned Panel. American Journal of Roentgenology, 224(5). https://doi.org/10.2214/ajr.24.32458

Vancouver

Wells JR, Christianson O, Gress DA, Gingold E, Jacobs J, Boedeker K, et al. The New CMS Measure of Excessive Radiation Dose or Inadequate Image Quality in CT: Issues and Ambiguities—Perspectives From an AAPM-Commissioned Panel. American Journal of Roentgenology. 2025;224(5). doi:10.2214/ajr.24.32458

BibTeX
@article{Wells2025,
  author = {Wells, Jered R and Christianson, Olav and Gress, Dustin A and Gingold, Eric and Jacobs, Jurgen and Boedeker, Kirsten and Ramirez-Giraldo, Juan Carlos and Yu, Lifeng and McNitt-Gray, Michael and Samei, Ehsan},
  title = {The New CMS Measure of Excessive Radiation Dose or Inadequate Image Quality in CT: Issues and Ambiguities—Perspectives From an AAPM-Commissioned Panel},
  journal = {American Journal of Roentgenology},
  year = {2025},
  volume = {224},
  number = {5},
  doi = {10.2214/ajr.24.32458}
}
Kostenlos starten →