Revision of ocular biometry using three-dimensional Super Formula for intraocular lens power calculation
Journal of Clinical Ophthalmology and Research · 2026-07 · 14 (3) · 260-264
DOI: 10.4103/jcor.jcor_67_26 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Ophthalmology and Research, online erschienen am 05.08.2026. Verfasst von R Ashik und 2 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
The purpose of this study was to evaluate whether the three-dimensional (3D) Super Formula can be used to assess accuracy in ocular biometry.
Setting
The study setting was the department of ophthalmology, a tertiary care hospital in Central India.
Design
The study design was a prospective observational study. Materials and Methods: Seventy-four eyes with senile cataract underwent biometry using the IOLMaster 500. From each series of readings, either the emmetropia power or the lowest negative power closest to emmetropia was chosen. This intraocular lens (IOL) power, along with axial length and averaged keratometry (K), was computed using the Ladas 3D online calculator. Plots were noted as inside or outside the shaded zone of the Ladas 3D graph. Following cataract surgery, absolute refractive error (ARE) was calculated at 6 weeks as the difference between spherical equivalent and predicted refractive error.
Results
SRK/T was most used (74.3%), followed by Holladay (17.6%) and Hoffer Q (8.1%). Accuracy did not differ significantly among formulae ( P = 0.053). Holladay achieved the highest proportion of eyes with ARE
Zitieren
APA
Ashik, R., Khan, L., & Mondal, K. (2026). Revision of ocular biometry using three-dimensional Super Formula for intraocular lens power calculation. Journal of Clinical Ophthalmology and Research, 14(3), 260-264. https://doi.org/10.4103/jcor.jcor_67_26
Vancouver
Ashik R, Khan L, Mondal K. Revision of ocular biometry using three-dimensional Super Formula for intraocular lens power calculation. Journal of Clinical Ophthalmology and Research. 2026;14(3):260-264. doi:10.4103/jcor.jcor_67_26
BibTeX
@article{Ashik2026,
author = {Ashik, R and Khan, Lubna and Mondal, Kiu},
title = {Revision of ocular biometry using three-dimensional Super Formula for intraocular lens power calculation},
journal = {Journal of Clinical Ophthalmology and Research},
year = {2026},
volume = {14},
number = {3},
pages = {260--264},
doi = {10.4103/jcor.jcor_67_26}
}