Comparing the Accuracy of the Kane, Barrett Universal II, Hill-Radial Basis Function, Emmetropia Verifying Optical, and Ladas Super Formula Intraocular Lens Power Calculation Formulas
Clinical Ophthalmology · 2023-09 · Volume 17 · 2643-2652
DOI: 10.2147/opth.s417865 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Ophthalmology, 2023-09. Verfasst von Majid Moshirfar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Hoopes Vision Research Center, Hoopes Vision, Draper, UT, USA. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).
Abstract (Originalsprache)
Purpose
To assess the accuracy of five new-generation intraocular lens (IOL) power formulas: Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO) Formula, Hill-Radial Basis Function (Hill-RBF), Kane Formula, and Ladas Super Formula (LSF). Patients and Methods: This is a retrospective single-surgeon study from a refractive clinic and clinical research center in Draper, UT, USA. The primary outcome measures were mean absolute error (MAE) and median absolute error (MedAE). Secondary outcome measures were the standard deviation (SD) of each formula's refractive prediction errors (RPE) and the percentage of eyes within ±0.50D. Refractive predictions were compared to the postoperative spherical equivalent to determine the RPE for each formula. RPEs were optimized, and MAE, MedAE, SD of the AME, and percent of eyes achieving RPEs within the specified ranges of ±0.125 D, ±0.25 D, ±0.50 D, ±0.75 D, ±1.0 D were calculated. Subgroup analysis between different axial lengths was attempted but yielded insufficient statistical power to draw meaningful conclusions.
Results
A total of 103 eyes of 103 patients were included in our study after applying inclusion and exclusion criteria to 606 eyes from 2019 to 2021. Formulas ranked in ascending order by MAE were Kane, EVO, BUII, Hill-RBF, and LSF. The ascending rankings of MedAE were Kane, BUII, Hill-RBF, EVO, Ladas. Kane had a significantly lower MAE than Hill-RBF (p
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Hoopes Vision Research Center, Hoopes Vision, Draper, UT, USA.
- John A. Moran Eye Center, University of Utah School of Medicine, Salt Lake City, UT, USA.
- Utah Lions Eye Bank, Murray, UT, USA.
- University of Arizona College of Medicine - Phoenix, Phoenix, AZ, USA.
- Phoenix Veterans Affairs Health Care System, Phoenix, AZ, USA.
ORCID-Profile: Majid Moshirfar, Alex H Brown, Chase Irwin, Yasmyne C Ronquillo, Phillip C Hoopes
Zitieren
APA
Moshirfar, M., Sulit, C. A., Brown, A. H., Irwin, C., Ronquillo, Y. C., & Hoopes, P. C. (2023). Comparing the Accuracy of the Kane, Barrett Universal II, Hill-Radial Basis Function, Emmetropia Verifying Optical, and Ladas Super Formula Intraocular Lens Power Calculation Formulas. Clinical Ophthalmology, Volume 17, 2643-2652. https://doi.org/10.2147/opth.s417865
Vancouver
Moshirfar M, Sulit CA, Brown AH, Irwin C, Ronquillo YC, Hoopes PC. Comparing the Accuracy of the Kane, Barrett Universal II, Hill-Radial Basis Function, Emmetropia Verifying Optical, and Ladas Super Formula Intraocular Lens Power Calculation Formulas. Clinical Ophthalmology. 2023;Volume 17:2643-2652. doi:10.2147/opth.s417865
BibTeX
@article{Moshirfar2023,
author = {Moshirfar, Majid and Sulit, Christian A and Brown, Alex H and Irwin, Chase and Ronquillo, Yasmyne C and Hoopes, Phillip C},
title = {Comparing the Accuracy of the Kane, Barrett Universal II, Hill-Radial Basis Function, Emmetropia Verifying Optical, and Ladas Super Formula Intraocular Lens Power Calculation Formulas},
journal = {Clinical Ophthalmology},
year = {2023},
volume = {Volume 17},
pages = {2643--2652},
doi = {10.2147/opth.s417865}
}
EUVIMED