EUVIMEDOpdag EUVIMED
Open access

Technical Feasibility of a Multimodal Electro-Optical and Infrared Imaging Pipeline for Postoperative Wound Assessment After Total Knee Arthroplasty: Formative Evaluation Study

Tej S Ranade iD, Emily Hu iD, Kadambari Beelwar iD, Sandeep Boddeda iD, Praharsha Mulpur iD, Adarsh Annapareddy iD, A V Gurava Reddy iD

JMIR Formative Research · 2026

DOI: 10.2196/99244 ↗

At a glance

Journal article in JMIR Formative Research, 2026. Written by Tej S Ranade and 6 co-authors. Institution: Truss Health, Inc., Las Vegas, NV, United States. Major MEDLINE topics: Arthroplasty, Replacement, Knee, Optical Imaging, Postoperative Complications. 34 references. The full text is freely available in PubMed Central.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Early detection and monitoring of wound-related complications after total knee arthroplasty (TKA) are critical to optimize outcomes and preserve implants. Conventional postoperative monitoring relies on in-person assessment and patient-reported symptoms, which may delay recognition. Noncontact imaging acquired in the clinic or at home offers a potential route to earlier and more consistent assessment.

Objective

This study aimed to evaluate the technical feasibility and performance of a multimodal AI system integrating electro-optical (EO) and infrared imaging for postoperative wound assessment following TKA and to explore clinical factors associated with early complications.

Methods

We conducted a single-center prospective cohort study of 749 patients undergoing primary TKA. Patients underwent standardized multimodal data collection at scheduled postoperative visits. EO-based models localized surgical landmarks and segmented complication-oriented tissue states; a fine-tuned vision-language model provided protocol verification and contextual visual reasoning. EO landmarks mapped to thermal space via deterministic alignment, followed by infrared region-of-interest segmentation and thermal classification. Each module was evaluated on a defined held-out set. The thermal classifier was assessed out-of-fold under 5-fold cross-validation with folds grouped by patient, in knees imaged on postoperative day 14 or later. Discrimination for clinician-adjudicated infection-related complications served as the primary outcome. Comorbidities and baseline laboratory values were explored for associations with complications.

Results

Among 749 patients, 26 (3.5%) had a clinician-adjudicated infection-related complication. On held-out evaluation, the EO landmark detector reached a sensitivity of 0.967 (95% CI 0.954-0.979) and positive predictive value of 0.955 (95% CI 0.940-0.970), and the wound-tissue segmentation model reached a sensitivity of 0.845 (95% CI 0.833-0.857) and positive predictive value of 0.759 (95% CI 0.744-0.772). Infrared region-of-interest extraction isolated the surgical field with a mean intersection-over-union of 0.985 (SD 0.008; 95% CI 0.984-0.986) across 178 held-out patients. The trained thermal classifier discriminated infected scans with an area under the receiver operating characteristic curve (AUROC) of 0.978 (95% CI 0.959-0.992) in out-of-fold, patient-grouped cross-validation. At a representative operating point, sensitivity was 0.808 (95% CI 0.65-0.92), specificity 0.974 (95% CI 0.96-0.99), positive predictive value 0.618 (95% CI 0.49-0.78), and negative predictive value 0.990 (95% CI 0.98-1.00). Exploratory analyses showed nominal associations of chronic kidney disease and diabetes mellitus with postoperative complications that did not remain significant after multiplicity correction.

Conclusions

In this formative study, a multimodal EO and infrared imaging pipeline demonstrated technical feasibility for postoperative wound assessment following TKA, providing noncontact discrimination of infection-related complications that compared favorably with established adjuncts. This work provides proof-of-concept for multimodal imaging-based assessment and defines the technical requirements for the prospective, multicenter external validation needed to establish clinical utility.

Subjects

MeSH terms (MEDLINE)

Arthroplasty, Replacement, KneeOptical ImagingPostoperative ComplicationsHumansFemaleProspective StudiesAgedFeasibility StudiesMaleMiddle AgedAged, 80 and overInfrared Rays

Author keywords

AIinfrared imagingknee arthroplastyperiprosthetic joint infectionpostoperative complicationsremote monitoring

Authors and institutions

  • Truss Health, Inc., Las Vegas, NV, United States.
  • Sunshine Bone and Joint Institute, Krishna Institute of Medical Sciences, Begumpet, Telangana, India.

ORCID profiles: Tej S Ranade, Emily Hu, Kadambari Beelwar, Sandeep Boddeda, Praharsha Mulpur, Adarsh Annapareddy, A V Gurava Reddy

Cite

APA

Ranade, T. S., Hu, E., Beelwar, K., Boddeda, S., Mulpur, P., Annapareddy, A., & Gurava Reddy, A. V. (2026). Technical Feasibility of a Multimodal Electro-Optical and Infrared Imaging Pipeline for Postoperative Wound Assessment After Total Knee Arthroplasty: Formative Evaluation Study. JMIR Formative Research. https://doi.org/10.2196/99244

Vancouver

Ranade TS, Hu E, Beelwar K, Boddeda S, Mulpur P, Annapareddy A, et al. Technical Feasibility of a Multimodal Electro-Optical and Infrared Imaging Pipeline for Postoperative Wound Assessment After Total Knee Arthroplasty: Formative Evaluation Study. JMIR Formative Research. 2026. doi:10.2196/99244

BibTeX
@article{Ranade2026,
  author = {Ranade, Tej S and Hu, Emily and Beelwar, Kadambari and Boddeda, Sandeep and Mulpur, Praharsha and Annapareddy, Adarsh and Gurava Reddy, A V},
  title = {Technical Feasibility of a Multimodal Electro-Optical and Infrared Imaging Pipeline for Postoperative Wound Assessment After Total Knee Arthroplasty: Formative Evaluation Study},
  journal = {JMIR Formative Research},
  year = {2026},
  doi = {10.2196/99244}
}
Start for free →