EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non‐invasive quantitative assessment of induced component displacement can safely and accurately diagnose tibial component loosening in patients: A prospective diagnostic study

George S Buijs, Arthur J Kievit, Maaike A Ter Wee, Caroline Magg, Johannes G G Dobbe, Geert J Streekstra, Matthias U Schafroth, Leendert Blankevoort

Knee Surgery, Sports Traumatology, Arthroscopy · 2025

DOI: 10.1002/ksa.12299 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2025. Verfasst von George S Buijs und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery and Sport Medicine, Amsterdam UMC, location AMC, Amsterdam, The Netherlands. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Prosthesis Failure, Knee Prosthesis, Tibia. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Amsterdam University Medical Center.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Aseptic loosening often requires major, expensive and invasive revision surgery. Current diagnostic modalities merely show indirect signs of loosening. A recent proof of concept study proposed a non‐invasive technique for the quantitative and visual assessment of implant movement as a diagnostic aid for tibial component loosening. The primary research question addressed is whether this novel diagnostic modality can safely and effectively aid the diagnosis of aseptic loosening.

Methods

This clinical study included patients suspected of aseptic total knee arthroplasty (TKA) loosening listed for revision surgery and asymptomatic patients. Safety was evaluated using a numerical rating scale (NRS) for discomfort and by registration of adverse events. Feasibility was assessed by recording the duration and ease of the procedure. Intra‐ and interrater reliability were evaluated. In symptomatic patients, diagnostic accuracy metrics were evaluated with intra‐operative assessment as a reference test.

Results

In total, 34 symptomatic and 38 asymptomatic knees with a TKA were analysed. The median NRS for discomfort during loading was 6 (interquartile range [IQR]: 3.75–7.00) in symptomatic patients and 2 (IQR: 1.00–3.00) in asymptomatic patients. No adverse events were reported. The majority of users found the use of the loading device easy. The median time spent in the computed tomography room was 9 min (IQR: 8.00–11.00). Excellent to good intra‐ and interrater reliabilities were achieved. Diagnostic accuracy analysis resulted in a sensitivity of 0.91 (95% confidence interval [CI]: 0.72–0.97) and a specificity of 0.72 (95% CI: 0.43–0.90).

Conclusions

The proposed diagnostic method is safe, feasible, reliable and accurate in aiding the diagnosis of aseptic tibial component loosening. Level of Evidence Level II.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeProsthesis FailureKnee ProsthesisTibiaHumansFemaleMaleProspective StudiesAgedMiddle AgedReproducibility of ResultsReoperationFeasibility Studies

Stichwörter der Autor:innen

aseptic looseningcomputed tomographydiagnostic testimagingknee arthroplasty

Autor:innen und Institutionen

  • Department of Orthopedic Surgery and Sport Medicine, Amsterdam UMC, location AMC, Amsterdam, The Netherlands.
  • Amsterdam Movement Sciences, Musculoskeletal Health, Meibergdreef 9, Amsterdam, The Netherlands.
  • Department of Biomedical Engineering and Physics, Amsterdam UMC, location AMC, University of Amsterdam, Amsterdam, The Netherlands.
  • Quantitative Healthcare Analysis (QurAI) Group, Informatics Institute, University of Amsterdam, Amsterdam, The Netherlands.

Förderung

  • Amsterdam University Medical Center

Zitieren

APA

Buijs, G. S., Kievit, A. J., Ter Wee, M. A., Magg, C., Dobbe, J. G. G., Streekstra, G. J., Schafroth, M. U., & Blankevoort, L. (2025). Non‐invasive quantitative assessment of induced component displacement can safely and accurately diagnose tibial component loosening in patients: A prospective diagnostic study. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12299

Vancouver

Buijs GS, Kievit AJ, Ter Wee MA, Magg C, Dobbe JGG, Streekstra GJ, et al. Non‐invasive quantitative assessment of induced component displacement can safely and accurately diagnose tibial component loosening in patients: A prospective diagnostic study. Knee Surgery, Sports Traumatology, Arthroscopy. 2025. doi:10.1002/ksa.12299

BibTeX
@article{Buijs2025,
  author = {Buijs, George S and Kievit, Arthur J and Ter Wee, Maaike A and Magg, Caroline and Dobbe, Johannes G G and Streekstra, Geert J and Schafroth, Matthias U and Blankevoort, Leendert},
  title = {Non‐invasive quantitative assessment of induced component displacement can safely and accurately diagnose tibial component loosening in patients: A prospective diagnostic study},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2025},
  doi = {10.1002/ksa.12299}
}
Kostenlos starten →