EUVIMEDEUVIMED entdecken
Open Access

Technical Feasibility of a Multimodal Electro-Optical and Infrared Imaging Pipeline for Postoperative Wound Assessment After Total Knee Arthroplasty: Formative Evaluation Study

Tej S Ranade iD, Emily Hu iD, Kadambari Beelwar iD, Sandeep Boddeda iD, Praharsha Mulpur iD, Adarsh Annapareddy iD, A V Gurava Reddy iD

JMIR Formative Research · 2026

DOI: 10.2196/99244 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JMIR Formative Research, 2026. Verfasst von Tej S Ranade und 6 weiteren Autor:innen. Beteiligte Einrichtung: Truss Health, Inc., Las Vegas, NV, United States. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Optical Imaging, Postoperative Complications. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Early detection and monitoring of wound-related complications after total knee arthroplasty (TKA) are critical to optimize outcomes and preserve implants. Conventional postoperative monitoring relies on in-person assessment and patient-reported symptoms, which may delay recognition. Noncontact imaging acquired in the clinic or at home offers a potential route to earlier and more consistent assessment.

Objective

This study aimed to evaluate the technical feasibility and performance of a multimodal AI system integrating electro-optical (EO) and infrared imaging for postoperative wound assessment following TKA and to explore clinical factors associated with early complications.

Methods

We conducted a single-center prospective cohort study of 749 patients undergoing primary TKA. Patients underwent standardized multimodal data collection at scheduled postoperative visits. EO-based models localized surgical landmarks and segmented complication-oriented tissue states; a fine-tuned vision-language model provided protocol verification and contextual visual reasoning. EO landmarks mapped to thermal space via deterministic alignment, followed by infrared region-of-interest segmentation and thermal classification. Each module was evaluated on a defined held-out set. The thermal classifier was assessed out-of-fold under 5-fold cross-validation with folds grouped by patient, in knees imaged on postoperative day 14 or later. Discrimination for clinician-adjudicated infection-related complications served as the primary outcome. Comorbidities and baseline laboratory values were explored for associations with complications.

Results

Among 749 patients, 26 (3.5%) had a clinician-adjudicated infection-related complication. On held-out evaluation, the EO landmark detector reached a sensitivity of 0.967 (95% CI 0.954-0.979) and positive predictive value of 0.955 (95% CI 0.940-0.970), and the wound-tissue segmentation model reached a sensitivity of 0.845 (95% CI 0.833-0.857) and positive predictive value of 0.759 (95% CI 0.744-0.772). Infrared region-of-interest extraction isolated the surgical field with a mean intersection-over-union of 0.985 (SD 0.008; 95% CI 0.984-0.986) across 178 held-out patients. The trained thermal classifier discriminated infected scans with an area under the receiver operating characteristic curve (AUROC) of 0.978 (95% CI 0.959-0.992) in out-of-fold, patient-grouped cross-validation. At a representative operating point, sensitivity was 0.808 (95% CI 0.65-0.92), specificity 0.974 (95% CI 0.96-0.99), positive predictive value 0.618 (95% CI 0.49-0.78), and negative predictive value 0.990 (95% CI 0.98-1.00). Exploratory analyses showed nominal associations of chronic kidney disease and diabetes mellitus with postoperative complications that did not remain significant after multiplicity correction.

Conclusions

In this formative study, a multimodal EO and infrared imaging pipeline demonstrated technical feasibility for postoperative wound assessment following TKA, providing noncontact discrimination of infection-related complications that compared favorably with established adjuncts. This work provides proof-of-concept for multimodal imaging-based assessment and defines the technical requirements for the prospective, multicenter external validation needed to establish clinical utility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeOptical ImagingPostoperative ComplicationsHumansFemaleProspective StudiesAgedFeasibility StudiesMaleMiddle AgedAged, 80 and overInfrared Rays

Stichwörter der Autor:innen

AIinfrared imagingknee arthroplastyperiprosthetic joint infectionpostoperative complicationsremote monitoring

Autor:innen und Institutionen

  • Truss Health, Inc., Las Vegas, NV, United States.
  • Sunshine Bone and Joint Institute, Krishna Institute of Medical Sciences, Begumpet, Telangana, India.

ORCID-Profile: Tej S Ranade, Emily Hu, Kadambari Beelwar, Sandeep Boddeda, Praharsha Mulpur, Adarsh Annapareddy, A V Gurava Reddy

Zitieren

APA

Ranade, T. S., Hu, E., Beelwar, K., Boddeda, S., Mulpur, P., Annapareddy, A., & Gurava Reddy, A. V. (2026). Technical Feasibility of a Multimodal Electro-Optical and Infrared Imaging Pipeline for Postoperative Wound Assessment After Total Knee Arthroplasty: Formative Evaluation Study. JMIR Formative Research. https://doi.org/10.2196/99244

Vancouver

Ranade TS, Hu E, Beelwar K, Boddeda S, Mulpur P, Annapareddy A, et al. Technical Feasibility of a Multimodal Electro-Optical and Infrared Imaging Pipeline for Postoperative Wound Assessment After Total Knee Arthroplasty: Formative Evaluation Study. JMIR Formative Research. 2026. doi:10.2196/99244

BibTeX
@article{Ranade2026,
  author = {Ranade, Tej S and Hu, Emily and Beelwar, Kadambari and Boddeda, Sandeep and Mulpur, Praharsha and Annapareddy, Adarsh and Gurava Reddy, A V},
  title = {Technical Feasibility of a Multimodal Electro-Optical and Infrared Imaging Pipeline for Postoperative Wound Assessment After Total Knee Arthroplasty: Formative Evaluation Study},
  journal = {JMIR Formative Research},
  year = {2026},
  doi = {10.2196/99244}
}
Kostenlos starten →