EUVIMEDObjevte EUVIMED
Open access

Continuous Glucose Monitoring Data Compression Using Peak-Nadir Encoding in Diabetes: Method Development and Evaluation

Clara Bender, Line Davidsen, Søren Schou Olesen, Simon Cichosz

JMIR Biomedical Engineering · 2026-07-20 · 11 · e91959-e91959

DOI: 10.2196/91959 ↗

At a glance

Journal article in JMIR Biomedical Engineering, published online on 2026-07-20. Written by Clara Bender and 3 co-authors. Institution: Department of Health Science and Technology, Aalborg University, Selma Lagerløfs Vej 249, Gistrup, North Denmark, 9260, Denmark, 45 99403809. 39 references. The full text is freely available in PubMed Central.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Continuous glucose monitoring (CGM) generates high-frequency time-series data, creating challenges for efficient storage, transmission, and analysis.

Objective

This study aimed to develop and evaluate a CGM-specific compression method that achieves high compression ratios while preserving signal fidelity and clinically relevant glycemic metrics.

Methods

We introduce a content-based encoding approach (PN+) that represents CGM profiles using physiologically salient landmarks: glucose peaks and nadirs and a small set of optimally selected support points. Reconstruction is performed using piecewise cubic Hermite interpolation. PN+ was evaluated against peaks and nadirs only, uniform downsampling, piecewise aggregate approximation, and autoencoder-based compression. Performance was assessed across multiple compression ratios using 2 complementary datasets: 40,000 synthetic CGM profiles and real-world CGM data from a randomized crossover trial (558 days from 30 patients). Performance was evaluated using compression ratio, mean absolute error, and R 2 between original and reconstructed CGM-derived clinical metrics.

Results

At a compression ratio of 13 (22 points per 24-hour profile), PN+ achieved substantially lower reconstruction error than comparator methods (mean absolute error=0.77 vs 2.75-3.45) and consistently higher R 2 values across glycemic metrics. Improvements were most pronounced for excursion-sensitive measures such as mean amplitude of glycemic excursions, where PN+ reduced error by more than 4-fold compared with downsampling, piecewise aggregate approximation, and autoencoders. These performance advantages were preserved in heterogeneous real-world data. Encoding and decoding required less than 0.2 seconds per profile, supporting practical scalability.

Conclusions

PN+ enables robust CGM data compression by explicitly preserving physiologically meaningful glucose dynamics. The method outperforms generic compression techniques in reconstructing clinically relevant metrics while maintaining low computational overhead, making it well suited for large-scale CGM storage, interoperability, and downstream analytics.

Subjects

Author keywords

CGMcompressioncontinuous glucose monitoringdatadiabetesencodingreconstructionsignal

Authors and institutions

  • Department of Health Science and Technology, Aalborg University, Selma Lagerløfs Vej 249, Gistrup, North Denmark, 9260, Denmark, 45 99403809.
  • Department of Clinical Medicine, Aalborg University Hospital, Aalborg, North Denmark, Denmark.
  • Centre for Pancreatic Diseases and Mech-Sense, Department of Gastroenterology and Hepatology, Aalborg University Hospital, Aalborg, Denmark.

Cite

APA

Bender, C., Davidsen, L., Olesen, S. S., & Cichosz, S. (2026). Continuous Glucose Monitoring Data Compression Using Peak-Nadir Encoding in Diabetes: Method Development and Evaluation. JMIR Biomedical Engineering, 11, e91959-e91959. https://doi.org/10.2196/91959

Vancouver

Bender C, Davidsen L, Olesen SS, Cichosz S. Continuous Glucose Monitoring Data Compression Using Peak-Nadir Encoding in Diabetes: Method Development and Evaluation. JMIR Biomedical Engineering. 2026;11:e91959-e91959. doi:10.2196/91959

BibTeX
@article{Bender2026,
  author = {Bender, Clara and Davidsen, Line and Olesen, Søren Schou and Cichosz, Simon},
  title = {Continuous Glucose Monitoring Data Compression Using Peak-Nadir Encoding in Diabetes: Method Development and Evaluation},
  journal = {JMIR Biomedical Engineering},
  year = {2026},
  volume = {11},
  pages = {e91959--e91959},
  doi = {10.2196/91959}
}