Bioelectrical impedance analysis versus dual-energy X-ray absorptiometry for sarcopenia assessment in type 2 diabetes mellitus: A systematic review and meta-analysis

Shobhit Raj, Sahana Shetty, Renuka Suvarna, Girish Thunga, Varashree Bolar Suryakanth

PLOS One · 20.11.2026 · 21 (11) · e0353604

DOI: 10.1371/journal.pone.0353604 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift PLOS One, online erschienen am 20.11.2026. Verfasst von Shobhit Raj und 4 weiteren Autor:innen. Die Arbeit nennt 89 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Sarcopenia is common in type 2 diabetes mellitus (T2DM). Bioelectrical impedance analysis (BIA) is cheaper and more accessible than dual-energy X-ray absorptiometry (DXA). We assessed whether BIA can replace DXA for measuring muscle mass and classifying low muscle mass in adults with T2DM.

Methods

PubMed/MEDLINE, Embase, Scopus, Web of Science and CINAHL were searched to March 2026 (updated 7 October 2026) for studies measuring muscle mass with both methods in adults with T2DM. Risk of bias was assessed with QUADAS-C. The primary outcome was Bland–Altman agreement (bias, DXA − BIA; population limits of agreement); classification, diagnostic accuracy and correlation (association only) were secondary. Random-effects models used restricted maximum likelihood with Hartung–Knapp intervals; certainty was rated with GRADE.

Results

Seven studies (646 participants, six countries) were included. For whole-body fat-free mass (three studies), the pooled bias was +0.82 kg (95% CI −0.69 to +2.34; population limits of agreement −6.4 to +8.0 kg). For appendicular lean-mass indices (three studies), the bias was −0.13 kg/m 2 (95% CI −1.32 to +1.06; I 2 = 98%; limits −1.8 to +1.5 kg/m 2 ). In three studies classifying low muscle mass by both methods, the pooled difference in proportions (BIA − DXA) was +3.6 percentage points (95% CI −8.6 to +15.7). With the same thresholds for both methods (two studies), BIA sensitivity was 71% and 91% and specificity 94% and 64%. Estimates were strongly correlated (r = 0.90), reflecting association, not agreement. Certainty of evidence was low or very low.

Conclusions

In adults with T2DM, BIA and DXA showed no clear average difference, but individual estimates and classifications differed too much for interchangeable use. Where DXA is unavailable, standardised BIA may support initial assessment, but results that would change management, particularly near diagnostic thresholds, should be confirmed with DXA.

Zitieren

APA

Raj, S., Shetty, S., Suvarna, R., Thunga, G., & Suryakanth, V. B. (2026). Bioelectrical impedance analysis versus dual-energy X-ray absorptiometry for sarcopenia assessment in type 2 diabetes mellitus: A systematic review and meta-analysis. PLOS One, 21(11), e0353604. https://doi.org/10.1371/journal.pone.0353604

Vancouver

Raj S, Shetty S, Suvarna R, Thunga G, Suryakanth VB. Bioelectrical impedance analysis versus dual-energy X-ray absorptiometry for sarcopenia assessment in type 2 diabetes mellitus: A systematic review and meta-analysis. PLOS One. 2026;21(11):e0353604. doi:10.1371/journal.pone.0353604

BibTeX
@article{Raj2026,
  author = {Raj, Shobhit and Shetty, Sahana and Suvarna, Renuka and Thunga, Girish and Suryakanth, Varashree Bolar},
  title = {Bioelectrical impedance analysis versus dual-energy X-ray absorptiometry for sarcopenia assessment in type 2 diabetes mellitus: A systematic review and meta-analysis},
  journal = {PLOS One},
  year = {2026},
  volume = {21},
  number = {11},
  pages = {e0353604},
  doi = {10.1371/journal.pone.0353604}
}
Kostenlos starten →