EUVIMEDEUVIMED entdecken
Open Access

Remote Vital Sign Monitoring in Acutely Unwell Hospital at Home Patients: Nonrandomized Feasibility Study

Rachel C Greer iD, Cristian Roman iD, Mayue Shi iD, Benn Gooch iD, Bethany K Lawson iD, Christopher Biggs iD, Clare Edwards iD, Sarah Vollam iD, Peter Watkinson iD, Lionel Tarassenko iD, Andrew Farmer iD, Daniel Lasserson iD

JMIR Formative Research · 2026

DOI: 10.2196/84233 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JMIR Formative Research, 2026. Verfasst von Rachel C Greer und 11 weiteren Autor:innen. Beteiligte Einrichtung: Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, England, United Kingdom. Hauptthemen laut MEDLINE: Vital Signs. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Remote vital sign monitoring of acute hospital at home (aHAH) patients is recommended in policy without clear guidance on implementation. While such monitoring has the potential to improve patient care, there is limited evidence for its feasibility and acceptability.

Objective

This study aimed to evaluate the feasibility and acceptability of using a remote, community-based monitoring system using a vital sign wearable patch and pulse oximeter in aHAH patients.

Methods

In this nonrandomized feasibility study, we recruited patients from an aHAH service in Oxford, United Kingdom, between January and October 2024. Eligible patients were aged 18 years and older with an acute illness (lower respiratory tract infection, cellulitis, urinary tract infection, systemic evidence of acute infection, acute kidney injury, or heart failure with acute fluid overload) requiring aHAH care. Pregnant women and those with contraindications to monitoring were excluded. Participants were asked to wear a chest patch to estimate their heart rate and respiratory rate (passive monitoring), and to intermittently check their oxygen saturations, blood pressure, and temperature (active monitoring). Participants were asked to complete a Technology Acceptance Questionnaire. All aHAH patients were screened. Recruitment was nonconsecutive due to the availability of the research team. Participants were monitored for 7 days or until discharge from the aHAH service, whichever was shorter. Fixed time windows were used to assess real-time vital sign data coverage during each participant’s monitoring period. The primary outcomes were the proportion of 4-hour monitoring windows with a recorded heart rate and 12-hour daytime windows with a recorded oxygen saturation level. Time-series analyses and descriptive statistics were used for quantitative data. Content analysis was used to analyze the open-ended comments in the questionnaire.

Results

In total, 29 participants were recruited and 3 immediately withdrew from the study. Participants were monitored for 4.8 (IQR 2.9-6.2) days on average. Overall, 89% (600/674) of the 4-hour monitoring windows had a heart rate and 75.4% (508/674) had a respiratory rate recorded in real-time. For the 12-hour daytime windows, 58.1% (75/129) had an oxygen saturation, 54.3% (70/129) had a blood pressure, and 51.2% (66/129) had a temperature recorded. Data coverage was higher for passive monitoring compared to active monitoring. Most participants who had capacity found the combined monitoring system easy to use and thought it was useful for their health care.

Conclusions

Remote monitoring of vital signs in aHAH patients is feasible. Good data coverage was achieved for the passive monitoring, which did not require specific actions by the participants or their caregivers. Further work is required to ascertain which patients would benefit most from this monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vital SignsHumansFeasibility StudiesFemaleMaleMiddle AgedAgedRemote Patient MonitoringAdultMonitoring, PhysiologicOximetryAged, 80 and overSurveys and QuestionnairesHeart RateUnited KingdomRespiratory Rate

Stichwörter der Autor:innen

hospital at homeremote monitoringvirtual wardsvital signswearables

Autor:innen und Institutionen

  • Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, England, United Kingdom.
  • NIHR Oxford Biomedical Research Centre, Oxford, England, United Kingdom.
  • Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford, England, United Kingdom.
  • Research Centre for Biomedical Engineering, School of Science and Technology, City St George's, University of London, London, England, United Kingdom.
  • Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, England, United Kingdom.
  • Department of Geratology, Acute Hospital at Home, Oxford University Hospitals NHS Foundation Trust, Oxford, England, United Kingdom.

ORCID-Profile: Rachel C Greer, Cristian Roman, Mayue Shi, Benn Gooch, Bethany K Lawson, Christopher Biggs, Clare Edwards, Sarah Vollam, Peter Watkinson, Lionel Tarassenko, Andrew Farmer, Daniel Lasserson

Zitieren

APA

Greer, R. C., Roman, C., Shi, M., Gooch, B., Lawson, B. K., Biggs, C., Edwards, C., Vollam, S., Watkinson, P., Tarassenko, L., Farmer, A., & Lasserson, D. (2026). Remote Vital Sign Monitoring in Acutely Unwell Hospital at Home Patients: Nonrandomized Feasibility Study. JMIR Formative Research. https://doi.org/10.2196/84233

Vancouver

Greer RC, Roman C, Shi M, Gooch B, Lawson BK, Biggs C, et al. Remote Vital Sign Monitoring in Acutely Unwell Hospital at Home Patients: Nonrandomized Feasibility Study. JMIR Formative Research. 2026. doi:10.2196/84233