EUVIMEDEUVIMED entdecken
KohortenstudieOpen Access

Effectiveness of Remote Patient Monitoring Equipped With an Early Warning System in Tertiary Care Hospital Wards: Retrospective Cohort Study

Pavithra Lakshman iD, Priyanka T Gopal iD, Sheen Khurdi iD

Journal of Medical Internet Research · 15.01.2025 · 27 · e56463

DOI: 10.2196/56463 ↗

Kurz gefasst

Kohortenstudie in der Zeitschrift Journal of Medical Internet Research, online erschienen am 15.01.2025. Verfasst von Pavithra Lakshman und 2 weiteren Autor:innen. Beteiligte Einrichtung: Hospital Administration, Ramaiah Memorial Hospital, Bengaluru, Karnataka, India. Hauptthemen laut MEDLINE: Tertiary Care Centers, Early Warning Score. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Monitoring vital signs in hospitalized patients is crucial for evaluating their clinical condition. While early warning scores like the modified early warning score (MEWS) are typically calculated 3 to 4 times daily through spot checks, they might not promptly identify early deterioration. Leveraging technologies that provide continuous monitoring of vital signs, combined with an early warning system, has the potential to identify clinical deterioration sooner. This approach empowers health care providers to intervene promptly and effectively.

Objective

This study aimed to assess the impact of a Remote Patient Monitoring System (RPMS) with an automated early warning system (R-EWS) on patient safety in noncritical care at a tertiary hospital. R-EWS performance was compared with a simulated Modified Early Warning System (S-MEWS) and a simulated threshold-based alert system (S-Threshold).

Methods

Patient outcomes, including intensive care unit (ICU) transfers due to deterioration and discharges for nondeteriorating cases, were analyzed in Ramaiah Memorial Hospital’s general wards with RPMS. Sensitivity, specificity, chi-square test for alert frequency distribution equality, and the average time from the first alert to ICU transfer in the last 24 hours was determined. Alert and patient distribution by tiers and vitals in R-EWS groups were examined.

Results

Analyzing 905 patients, including 38 with deteriorations, R-EWS, S-Threshold, and S-MEWS generated more alerts for deteriorating cases. R-EWS showed high sensitivity (97.37%) and low specificity (23.41%), S-Threshold had perfect sensitivity (100%) but low specificity (0.46%), and S-MEWS demonstrated moderate sensitivity (47.37%) and high specificity (81.31%). The average time from initial alert to clinical deterioration was at least 18 hours for RPMS and S-Threshold in deteriorating participants. R-EWS had increased alert frequency and a higher proportion of critical alerts for deteriorating cases.

Conclusions

This study underscores R-EWS role in early deterioration detection, emphasizing timely interventions for improved patient outcomes. Continuous monitoring enhances patient safety and optimizes care quality.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tertiary Care CentersEarly Warning ScoreHumansRetrospective StudiesMonitoring, PhysiologicFemaleMaleIntensive Care UnitsMiddle AgedVital SignsAgedClinical DeteriorationRemote Patient Monitoring

Stichwörter der Autor:innen

clinical informationcohort studycontinuous vitals monitoringdecision makingearly deterioration monitoringearly warning systemhospital wardspatient careremote patient monitoringretrospective

Autor:innen und Institutionen

  • Hospital Administration, Ramaiah Memorial Hospital, Bengaluru, Karnataka, India.

ORCID-Profile: Pavithra Lakshman, Priyanka T Gopal, Sheen Khurdi

Zitieren

APA

Lakshman, P., Gopal, P. T., & Khurdi, S. (2025). Effectiveness of Remote Patient Monitoring Equipped With an Early Warning System in Tertiary Care Hospital Wards: Retrospective Cohort Study. Journal of Medical Internet Research, 27, e56463. https://doi.org/10.2196/56463

Vancouver

Lakshman P, Gopal PT, Khurdi S. Effectiveness of Remote Patient Monitoring Equipped With an Early Warning System in Tertiary Care Hospital Wards: Retrospective Cohort Study. Journal of Medical Internet Research. 2025;27:e56463. doi:10.2196/56463

BibTeX
@article{Lakshman2025,
  author = {Lakshman, Pavithra and Gopal, Priyanka T and Khurdi, Sheen},
  title = {Effectiveness of Remote Patient Monitoring Equipped With an Early Warning System in Tertiary Care Hospital Wards: Retrospective Cohort Study},
  journal = {Journal of Medical Internet Research},
  year = {2025},
  volume = {27},
  pages = {e56463},
  doi = {10.2196/56463}
}
Kostenlos starten →