EUVIMEDExplore EUVIMED
Multizentrische StudieValidierungsstudieOpen access

Prediction of Blood Transfusion Need and Dose in Patients With Upper Gastrointestinal Bleeding: Retrospective Multicenter Prediction Model Study

Xiaoyu Li iD, Yuqin He iD, Mingyang Hou iD, Zhi Yu iD, Shuai Miao iD, Zhiyong Huang iD, Min Yang iD

JMIR Medical Informatics · 2026-08-04 · 14 · e83889-e83889

DOI: 10.2196/83889 ↗

At a glance

Multizentrische Studie in JMIR Medical Informatics, published online on 2026-08-04. Written by Xiaoyu Li and 6 co-authors. Institution: School of Microelectronics and Communication Engineering, Chongqing University, No. 174 Shazheng Street, Shapingba District, Chongqing, 400044, China…. Major MEDLINE topics: Blood Transfusion, Gastrointestinal Hemorrhage. 42 references. The full text is freely available in PubMed Central.

AbstractSubjectsBibliographic detailsCiteRelated studies

Abstract (original language)

Background

Transfusion thresholds in upper gastrointestinal bleeding are debated; hemoglobin cutoffs of 70‐80 g/L are widely cited yet inconsistently applied. Common risk scores offer limited individualized guidance and rarely provide calibrated, interpretable predictions for transfusion decisions.

Objective

This study aimed to develop and validate a two-stage, clinically constrained gradient-boosting framework (Medically Constrained Gradient Boosting [MCGB]) that predicts transfusion need and estimates transfusion dose with quantified uncertainty and to implement a prototype recommendation system for clinical use.

Methods

We analyzed a retrospective multicenter cohort of 849 adults with endoscopically confirmed upper gastrointestinal bleeding admitted to 3 hospitals in Chongqing, China (January 2019 to August 2025). Predictors available before the transfusion decision included demographics, first recorded vital signs, initial laboratory indices, and clinician-adjudicated etiology. Stage 1 used a calibrated classifier with prespecified monotonic constraints and stability-screened, clinically justified interactions. Stage 2 modeled transfusion dose via quantile predictions with conformal adjustment to generate 95% prediction intervals. Performance was assessed using a cross-site hold-out design. Overall, 2 hospitals were used as the development cohort, within which stratified 5-fold cross-validation was performed for model development, hyperparameter tuning, interaction screening, and calibration. The remaining hospital was held out as an independent test cohort for final evaluation. Hospital-wise alternating external testing was further conducted as a supplementary robustness analysis to assess performance stability across institutions. Classification performance was evaluated using discrimination metrics (area under the receiver operating characteristic curve and area under the precision-recall curve), calibration metrics, and decision-curve analysis; regression performance was evaluated using R ², mean absolute error, and prediction-interval coverage. A graphical user interface was implemented to enable clinicians to input patient data and obtain calibrated predictions of transfusion probability and corresponding dose recommendations.

Results

MCGB achieved strong discrimination and good calibration across subgroups (area under the receiver operating characteristic curve=0.97 and area under the precision-recall curve=0.91). At a reference probability threshold of .50, sensitivity, specificity, and F 1 -scores were 0.99, 0.87, and 0.85, respectively, providing a representative operating point for comparison. For dose prediction among transfused patients, MCGB achieved R ² of 0.95 and mean absolute error 0.04; 95% prediction-interval coverage was 0.94, indicating accurate point estimates with reliable uncertainty quantification. The software prototype further demonstrated feasibility of real-time decision support at the bedside.

Conclusions

MCGB provides calibrated, interpretable predictions of transfusion need and individualized dose in upper gastrointestinal bleeding and may support bedside decision-making and blood-bank planning, with a prototype interface demonstrating potential for clinical deployment. External validation in additional settings is warranted to confirm generalizability.

Subjects

MeSH terms (MEDLINE)

Blood TransfusionGastrointestinal HemorrhageAgedFemaleHumansMaleMiddle AgedChinaPrediction AlgorithmsRetrospective Studies

Author keywords

ROC curveblood transfusiondecision support systems, clinicalelectronic health recordsgastrointestinal hemorrhagemachine learningreceiver operating characteristicregression analysis

Authors and institutions

  • School of Microelectronics and Communication Engineering, Chongqing University, No. 174 Shazheng Street, Shapingba District, Chongqing, 400044, China, 86 023-65678860.
  • Bioengineering College of Chongqing University, Chongqing University, Chongqing, 400044, China.
  • Department of Gastroenterology, Daping Hospital, Army Medical Center of PLA, Army Medical University, Chongqing, 400042, China.

ORCID profiles: Xiaoyu Li, Yuqin He, Mingyang Hou, Zhi Yu, Shuai Miao, Zhiyong Huang, Min Yang

Cite

APA

Li, X., He, Y., Hou, M., Yu, Z., Miao, S., Huang, Z., & Yang, M. (2026). Prediction of Blood Transfusion Need and Dose in Patients With Upper Gastrointestinal Bleeding: Retrospective Multicenter Prediction Model Study. JMIR Medical Informatics, 14, e83889-e83889. https://doi.org/10.2196/83889

Vancouver

Li X, He Y, Hou M, Yu Z, Miao S, Huang Z, et al. Prediction of Blood Transfusion Need and Dose in Patients With Upper Gastrointestinal Bleeding: Retrospective Multicenter Prediction Model Study. JMIR Medical Informatics. 2026;14:e83889-e83889. doi:10.2196/83889

BibTeX
@article{Li2026,
  author = {Li, Xiaoyu and He, Yuqin and Hou, Mingyang and Yu, Zhi and Miao, Shuai and Huang, Zhiyong and Yang, Min},
  title = {Prediction of Blood Transfusion Need and Dose in Patients With Upper Gastrointestinal Bleeding: Retrospective Multicenter Prediction Model Study},
  journal = {JMIR Medical Informatics},
  year = {2026},
  volume = {14},
  pages = {e83889--e83889},
  doi = {10.2196/83889}
}
Start for free →