Prediction of Blood Transfusion Need and Dose in Patients With Upper Gastrointestinal Bleeding: Retrospective Multicenter Prediction Model Study
JMIR Medical Informatics · 04.08.2026 · 14 · e83889-e83889
DOI: 10.2196/83889 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift JMIR Medical Informatics, online erschienen am 04.08.2026. Verfasst von Xiaoyu Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Microelectronics and Communication Engineering, Chongqing University, No. 174 Shazheng Street, Shapingba District, Chongqing, 400044, China…. Hauptthemen laut MEDLINE: Blood Transfusion, Gastrointestinal Hemorrhage. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Transfusion thresholds in upper gastrointestinal bleeding are debated; hemoglobin cutoffs of 70‐80 g/L are widely cited yet inconsistently applied. Common risk scores offer limited individualized guidance and rarely provide calibrated, interpretable predictions for transfusion decisions.
Objective
This study aimed to develop and validate a two-stage, clinically constrained gradient-boosting framework (Medically Constrained Gradient Boosting [MCGB]) that predicts transfusion need and estimates transfusion dose with quantified uncertainty and to implement a prototype recommendation system for clinical use.
Methods
We analyzed a retrospective multicenter cohort of 849 adults with endoscopically confirmed upper gastrointestinal bleeding admitted to 3 hospitals in Chongqing, China (January 2019 to August 2025). Predictors available before the transfusion decision included demographics, first recorded vital signs, initial laboratory indices, and clinician-adjudicated etiology. Stage 1 used a calibrated classifier with prespecified monotonic constraints and stability-screened, clinically justified interactions. Stage 2 modeled transfusion dose via quantile predictions with conformal adjustment to generate 95% prediction intervals. Performance was assessed using a cross-site hold-out design. Overall, 2 hospitals were used as the development cohort, within which stratified 5-fold cross-validation was performed for model development, hyperparameter tuning, interaction screening, and calibration. The remaining hospital was held out as an independent test cohort for final evaluation. Hospital-wise alternating external testing was further conducted as a supplementary robustness analysis to assess performance stability across institutions. Classification performance was evaluated using discrimination metrics (area under the receiver operating characteristic curve and area under the precision-recall curve), calibration metrics, and decision-curve analysis; regression performance was evaluated using R ², mean absolute error, and prediction-interval coverage. A graphical user interface was implemented to enable clinicians to input patient data and obtain calibrated predictions of transfusion probability and corresponding dose recommendations.
Results
MCGB achieved strong discrimination and good calibration across subgroups (area under the receiver operating characteristic curve=0.97 and area under the precision-recall curve=0.91). At a reference probability threshold of .50, sensitivity, specificity, and F 1 -scores were 0.99, 0.87, and 0.85, respectively, providing a representative operating point for comparison. For dose prediction among transfused patients, MCGB achieved R ² of 0.95 and mean absolute error 0.04; 95% prediction-interval coverage was 0.94, indicating accurate point estimates with reliable uncertainty quantification. The software prototype further demonstrated feasibility of real-time decision support at the bedside.
Conclusions
MCGB provides calibrated, interpretable predictions of transfusion need and individualized dose in upper gastrointestinal bleeding and may support bedside decision-making and blood-bank planning, with a prototype interface demonstrating potential for clinical deployment. External validation in additional settings is warranted to confirm generalizability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Microelectronics and Communication Engineering, Chongqing University, No. 174 Shazheng Street, Shapingba District, Chongqing, 400044, China, 86 023-65678860.
- Bioengineering College of Chongqing University, Chongqing University, Chongqing, 400044, China.
- Department of Gastroenterology, Daping Hospital, Army Medical Center of PLA, Army Medical University, Chongqing, 400042, China.
ORCID-Profile: Xiaoyu Li, Yuqin He, Mingyang Hou, Zhi Yu, Shuai Miao, Zhiyong Huang, Min Yang
Zitieren
APA
Li, X., He, Y., Hou, M., Yu, Z., Miao, S., Huang, Z., & Yang, M. (2026). Prediction of Blood Transfusion Need and Dose in Patients With Upper Gastrointestinal Bleeding: Retrospective Multicenter Prediction Model Study. JMIR Medical Informatics, 14, e83889-e83889. https://doi.org/10.2196/83889
Vancouver
Li X, He Y, Hou M, Yu Z, Miao S, Huang Z, et al. Prediction of Blood Transfusion Need and Dose in Patients With Upper Gastrointestinal Bleeding: Retrospective Multicenter Prediction Model Study. JMIR Medical Informatics. 2026;14:e83889-e83889. doi:10.2196/83889
BibTeX
@article{Li2026,
author = {Li, Xiaoyu and He, Yuqin and Hou, Mingyang and Yu, Zhi and Miao, Shuai and Huang, Zhiyong and Yang, Min},
title = {Prediction of Blood Transfusion Need and Dose in Patients With Upper Gastrointestinal Bleeding: Retrospective Multicenter Prediction Model Study},
journal = {JMIR Medical Informatics},
year = {2026},
volume = {14},
pages = {e83889--e83889},
doi = {10.2196/83889}
}