EUVIMEDEUVIMED entdecken
ValidierungsstudieQuerschnittstudieOpen Access

Heart Rate Estimation Using the Galaxy Watch During Maximal Cardiopulmonary Exercise Testing: Cross-Sectional Validation Study

Allan Inoue, João Paulo Ferreira Soares, Felipe Antunes-Santos, Alexandre Ferreira, Alberto Gonçalves, João Arthur Alcântara, Marcelo Rodrigues Dos Santos

JMIR Cardio · 16.04.2026 · 10 · e81917-e81917

DOI: 10.2196/81917 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift JMIR Cardio, online erschienen am 16.04.2026. Verfasst von Allan Inoue und 6 weiteren Autor:innen. Beteiligte Einrichtung: Health Data Lab, Sidia Institute of Science and Technology, Av. Autaz Mirim, 2211 - Distrito Industrial I, Manaus, 69075-155, Brazil, 55 (92) 3212-34…. Hauptthemen laut MEDLINE: Exercise Test, Heart Rate, Photoplethysmography. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Photoplethysmography-based smartwatches are increasingly used for continuous heart rate (HR) monitoring. Their accuracy has been demonstrated at rest or during low-intensity activity, but data are scarce for maximal-intensity exercise, when motion artifacts and rapid hemodynamic changes can degrade the photoplethysmography signal. Validating these devices under such demanding conditions is essential before they are applied to clinical exercise testing, athletic training, or remote health monitoring.

Objective

This study aimed to evaluate the validity of the Samsung Galaxy Watch 6 (GW6) in estimating HR throughout a graded, maximal ramp cardiopulmonary exercise test performed on a treadmill. A secondary aim was to explore whether measurement error varies across 5 predefined intensity zones (50%‐60%, 60%‐70%, 70%‐80%, 80%‐90%, and 90%‐100% of the maximum HR determined individually for each participant).

Methods

Overall, 55 healthy adults (30 men, 25 women; mean age 30.3, SD 8.2 years) completed a symptom-limited incremental treadmill protocol to volitional exhaustion. Simultaneous HR recordings were obtained from the GW6 (left arm) and a Polar H10 chest strap monitor, which served as the reference standards. For each intensity zone, the following agreement indices were computed: intraclass correlation coefficient (ICC), median absolute error, median absolute percentage error, and root mean squared error. Bland-Altman analysis was performed to quantify the mean bias and 95% limits of agreement between the GW6 and the Polar H10. Statistical significance was set at P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Exercise TestHeart RatePhotoplethysmographyHumansFemaleMaleAdultCross-Sectional StudiesReproducibility of Results

Stichwörter der Autor:innen

cardiopulmonary exercise testmaximal exercisephotoplethysmographysmartwatcheswearable

Autor:innen und Institutionen

  • Health Data Lab, Sidia Institute of Science and Technology, Av. Autaz Mirim, 2211 - Distrito Industrial I, Manaus, 69075-155, Brazil, 55 (92) 3212-3444.

Zitieren

APA

Inoue, A., Soares, J. P. F., Antunes-Santos, F., Ferreira, A., Gonçalves, A., Alcântara, J. A., & Dos Santos, M. R. (2026). Heart Rate Estimation Using the Galaxy Watch During Maximal Cardiopulmonary Exercise Testing: Cross-Sectional Validation Study. JMIR Cardio, 10, e81917-e81917. https://doi.org/10.2196/81917

Vancouver

Inoue A, Soares JPF, Antunes-Santos F, Ferreira A, Gonçalves A, Alcântara JA, et al. Heart Rate Estimation Using the Galaxy Watch During Maximal Cardiopulmonary Exercise Testing: Cross-Sectional Validation Study. JMIR Cardio. 2026;10:e81917-e81917. doi:10.2196/81917

BibTeX
@article{Inoue2026,
  author = {Inoue, Allan and Soares, João Paulo Ferreira and Antunes-Santos, Felipe and Ferreira, Alexandre and Gonçalves, Alberto and Alcântara, João Arthur and Dos Santos, Marcelo Rodrigues},
  title = {Heart Rate Estimation Using the Galaxy Watch During Maximal Cardiopulmonary Exercise Testing: Cross-Sectional Validation Study},
  journal = {JMIR Cardio},
  year = {2026},
  volume = {10},
  pages = {e81917--e81917},
  doi = {10.2196/81917}
}
Kostenlos starten →