EUVIMEDObjevte EUVIMED
Open access

An App-Based Remote Patient Monitoring System With Wrist and In-Ear Wearables in Gastrointestinal Oncology: Prospective Feasibility Pilot Study

Lara Kohn iD, Veit Scheble iD, Philip Storz iD, Anita Müller iD, Selcan Behiye Ulas iD, Fee Schmitt iD, Christian Thies iD, Nisar Malek iD

JMIR Cancer · 2025

DOI: 10.2196/64184 ↗

At a glance

Journal article in JMIR Cancer, 2025. Written by Lara Kohn and 7 co-authors. Institution: Center for Personalized Medicine, University Hospital Tübingen, Röntgenweg 9, Tübingen, 72076, Germany, 49 7071 29 82864, 49 7071 29 2727. Major MEDLINE topics: Wearable Electronic Devices, Mobile Applications, Gastrointestinal Neoplasms. Cited 5 times so far (Crossref); 32 references. The full text is freely available in PubMed Central.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Outpatient treatments, including targeted therapies, in oncology are on the rise. The implementation of remote patient monitoring (RPM) between therapy sessions has the potential to enhance patient care and therapy outcomes in the future.

Objective

This pilot study assessed the feasibility of a new, app-based RPM system (bwHealthApp) by capturing patient-reported outcomes (PROs) and vital parameters using a wrist- or in-ear wearable. The study examined adherence, acceptance, and satisfaction, as well as the differences between the two types of wearables.

Methods

Outpatients with gastrointestinal cancer receiving systemic therapies were invited to use and evaluate the bwHealthApp system for 1 month. The system was set up as an Android smartphone app to assess electronic PROs (ePROs) and connect to wearables for continuous vital sign measurements. A wrist wearable (Beurer AS99) that measured activity and heart rate or an in-ear wearable (Cosinuss Two) that measured heart rate, oxygen saturation, and temperature was used. The data were synchronized remotely to a web client. Outpatients were randomly assigned to the wrist wearable (n=17) or in-ear wearable (n=14) group. At the beginning, middle, and end of the study, patients (N=31) completed questionnaires on various feasibility aspects. Adherence to ePRO completion; wearable use, acceptance, and satisfaction; wearable data quantity and quality; and differences between the wearables were evaluated.

Results

The mean adherence to bwHealthApp including dropouts was 46% (449/971 days) for ePRO completion and 61% (593/971 days) for wearable use. The system was most frequently used during everyday activities. More than half of the participants were satisfied with bwHealthApp (18/30, 60%) and could imagine continued use (21/30, 70%). Notably, 70% (21/30) rated the system as easy to use. Participants recorded more than 20 million wearable measures; however, 29% (SD 22%, range 3%-76%) of temperature values and 33% (SD 25%, range 10%-92%) of oxygen saturation values were outside the physiological range. For heart rate, the mean proportion of excluded values was 10% (SD 11%, range 4%-48%; in-ear) and 11% (SD 8%, range 4%-33%; wrist). The frequency of use of the two wearables did not differ significantly ( t 29 =1.81; P =.08). The wrist wearable scored significantly better than the in-ear wearable regarding wearing comfort ( t 28 =−11.17; P =.03).

Conclusions

This bwHealthApp pilot study demonstrates the feasibility of RPM via a mobile app and wearable devices during outpatient systemic cancer therapy, including targeted therapies. The adherence level was moderate, and patients were generally satisfied with the system, although the wrist wearable received a higher rating. The system’s functionality may be enhanced through the integration of additional wearables. This pilot study serves as a foundational framework for long-term assessments examining RPM and clinical data to improve cancer treatments.

Subjects

MeSH terms (MEDLINE)

Wearable Electronic DevicesMobile ApplicationsGastrointestinal NeoplasmsHumansPilot ProjectsMaleFemaleFeasibility StudiesMiddle AgedProspective StudiesAgedWristPatient Reported Outcome MeasuresMonitoring, PhysiologicTelemedicinePatient SatisfactionAdultRemote Patient Monitoring

Author keywords

acceptabilityappcancerfeasibilitygastrointestinalmobile health (mHealth)pilotprecision medicineremote patient monitoringwearables

Authors and institutions

  • Center for Personalized Medicine, University Hospital Tübingen, Röntgenweg 9, Tübingen, 72076, Germany, 49 7071 29 82864, 49 7071 29 2727.
  • Clinic of Internal Medicine, University Hospital Tübingen, Tübingen, Germany.
  • Reutlingen Research Institute, Reutlingen University, Reutlingen, Germany.
  • M3 Research Center, University of Tübingen, Tübingen, Germany.

ORCID profiles: Lara Kohn, Veit Scheble, Philip Storz, Anita Müller, Selcan Behiye Ulas, Fee Schmitt, Christian Thies, Nisar Malek

Cite

APA

Kohn, L., Scheble, V., Storz, P., Müller, A., Ulas, S. B., Schmitt, F., Thies, C., & Malek, N. (2025). An App-Based Remote Patient Monitoring System With Wrist and In-Ear Wearables in Gastrointestinal Oncology: Prospective Feasibility Pilot Study. JMIR Cancer. https://doi.org/10.2196/64184

Vancouver

Kohn L, Scheble V, Storz P, Müller A, Ulas SB, Schmitt F, et al. An App-Based Remote Patient Monitoring System With Wrist and In-Ear Wearables in Gastrointestinal Oncology: Prospective Feasibility Pilot Study. JMIR Cancer. 2025. doi:10.2196/64184

BibTeX
@article{Kohn2025,
  author = {Kohn, Lara and Scheble, Veit and Storz, Philip and Müller, Anita and Ulas, Selcan Behiye and Schmitt, Fee and Thies, Christian and Malek, Nisar},
  title = {An App-Based Remote Patient Monitoring System With Wrist and In-Ear Wearables in Gastrointestinal Oncology: Prospective Feasibility Pilot Study},
  journal = {JMIR Cancer},
  year = {2025},
  doi = {10.2196/64184}
}
Start for free →