EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Continuous vital sign monitoring with Biobeat® wearable devices for post-ambulatory surgery patients: a pilot feasibility study

Julien Belliveau, Léo Pilote, Elliot Grange, Cédrick Zaouter, Maxim Roy iD, Florian Robin

Journal of Clinical Monitoring and Computing · 2025

DOI: 10.1007/s10877-025-01276-0 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Clinical Monitoring and Computing, 2025. Verfasst von Julien Belliveau und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of anesthesiology, Centre Hospitalier de l'Université de Montréal, 1051, Sanguinet, Montreal (Québec), H2X 0C1, Canada. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Vital Signs, Ambulatory Surgical Procedures, Postoperative Care. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: FSISSS (Health and Social Services Innovation Support Fund, Fond de soutien à l'innovation en santé et en services sociaux).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Improvement in anesthesia and surgical practices has enabled more patients, including those undergoing higher-risk surgeries, to be treated in outpatient settings. This shift creates a need for reliable postoperative monitoring at home. Wearable devices like the Biobeat® offer continuous, real-time monitoring of vital signs have remained largely untested for home use in this context.A prospective, single-center observational study was conducted at the Centre hospitalier de l'Université de Montréal (CHUM) from February to August 2023. Fifty eligible patients underwent continuous monitoring with the Biobeat® device for five days post-surgery, with data transmitted to CHUM's telehealth service. Feasibility was assessed by the percentage of patients without data loss during consecutive 2-hour intervals.Of the 50 patients enrolled, 49 completed the study, but all experienced some level of data loss. While 39.6% of patients maintained connectivity without complete data loss for 6-8-hour intervals, challenges included device discomfort, Bluetooth disconnection, and connectivity issues. Thirteen patients removed the device early due to discomfort or technical issues. Of the 3 patients who experienced post-operative complications, no data was available within 24 h prior to the episodes. Continuous vital signs monitoring is feasible for high-risk outpatient surgery patients; however, significant improvements are required in device reliability and data accessibility. Further studies are needed to refine the technology and develop reliable protocols for postoperative monitoring in the home setting.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesVital SignsAmbulatory Surgical ProceduresPostoperative CareHumansFeasibility StudiesPilot ProjectsFemaleMaleProspective StudiesMiddle AgedMonitoring, PhysiologicAgedAdultTelemedicineAged, 80 and overReproducibility of Results

Stichwörter der Autor:innen

MonitoringOutpatient surgeryWearable devices

Autor:innen und Institutionen

  • Department of anesthesiology, Centre Hospitalier de l'Université de Montréal, 1051, Sanguinet, Montreal (Québec), H2X 0C1, Canada.
  • Department of anesthesiology, University of Sherbrooke, 3001 12e Avenue N, Sherbrooke, J1H 5H3, Canada.
  • Division of Anaesthesiology, Department of Anaesthesiology, Pharmacology, Intensive Care and Emergency Medicine, Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Genève, 1205, Switzerland.
  • Department of anesthesiology, Centre Hospitalier de l'Université de Montréal, 1051, Sanguinet, Montreal (Québec), H2X 0C1, Canada. maxim.roy20@gmail.com.

ORCID-Profile: Maxim Roy

Förderung

  • FSISSS (Health and Social Services Innovation Support Fund, Fond de soutien à l'innovation en santé et en services sociaux)

Zitieren

APA

Belliveau, J., Pilote, L., Grange, E., Zaouter, C., Roy, M., & Robin, F. (2025). Continuous vital sign monitoring with Biobeat® wearable devices for post-ambulatory surgery patients: a pilot feasibility study. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-025-01276-0

Vancouver

Belliveau J, Pilote L, Grange E, Zaouter C, Roy M, Robin F. Continuous vital sign monitoring with Biobeat® wearable devices for post-ambulatory surgery patients: a pilot feasibility study. Journal of Clinical Monitoring and Computing. 2025. doi:10.1007/s10877-025-01276-0

BibTeX
@article{Belliveau2025,
  author = {Belliveau, Julien and Pilote, Léo and Grange, Elliot and Zaouter, Cédrick and Roy, Maxim and Robin, Florian},
  title = {Continuous vital sign monitoring with Biobeat® wearable devices for post-ambulatory surgery patients: a pilot feasibility study},
  journal = {Journal of Clinical Monitoring and Computing},
  year = {2025},
  doi = {10.1007/s10877-025-01276-0}
}
Kostenlos starten →