Wearable Bioimpedance Monitoring: Viewpoint for Application in Chronic Conditions
JMIR Biomedical Engineering · 2021-05-11 · 6 (2) · e22911
DOI: 10.2196/22911 ↗At a glance
Journal article in JMIR Biomedical Engineering, published online on 2021-05-11. Written by Willemijn Groenendaal and 2 co-authors. Institution: Imec the Netherlands / Holst Centre, Eindhoven, Netherlands. Cited 45 times so far (Crossref); 120 references. The full text is freely available in PubMed Central.
Abstract (original language)
Currently, nearly 6 in 10 US adults are suffering from at least one chronic condition. Wearable technology could help in controlling the health care costs by remote monitoring and early detection of disease worsening. However, in recent years, there have been disappointments in wearable technology with respect to reliability, lack of feedback, or lack of user comfort. One of the promising sensor techniques for wearable monitoring of chronic disease is bioimpedance, which is a noninvasive, versatile sensing method that can be applied in different ways to extract a wide range of health care parameters. Due to the changes in impedance caused by either breathing or blood flow, time-varying signals such as respiration and cardiac output can be obtained with bioimpedance. A second application area is related to body composition and fluid status (eg, pulmonary congestion monitoring in patients with heart failure). Finally, bioimpedance can be used for continuous and real-time imaging (eg, during mechanical ventilation). In this viewpoint, we evaluate the use of wearable bioimpedance monitoring for application in chronic conditions, focusing on the current status, recent improvements, and challenges that still need to be tackled.
Subjects
Author keywords
Authors and institutions
- Imec the Netherlands / Holst Centre, Eindhoven, Netherlands.
- Imec, Leuven, Belgium.
- One Planet Research Center, Wageningen, Netherlands.
- Department of Engineering Science, KU Leuven, Leuven, Belgium.
ORCID profiles: Willemijn Groenendaal, Seulki Lee, Chris van Hoof
Cite
APA
Groenendaal, W., Lee, S., & van Hoof, C. (2021). Wearable Bioimpedance Monitoring: Viewpoint for Application in Chronic Conditions. JMIR Biomedical Engineering, 6(2), e22911. https://doi.org/10.2196/22911
Vancouver
Groenendaal W, Lee S, van Hoof C. Wearable Bioimpedance Monitoring: Viewpoint for Application in Chronic Conditions. JMIR Biomedical Engineering. 2021;6(2):e22911. doi:10.2196/22911
BibTeX
@article{Groenendaal2021,
author = {Groenendaal, Willemijn and Lee, Seulki and van Hoof, Chris},
title = {Wearable Bioimpedance Monitoring: Viewpoint for Application in Chronic Conditions},
journal = {JMIR Biomedical Engineering},
year = {2021},
volume = {6},
number = {2},
pages = {e22911},
doi = {10.2196/22911}
}