PPG and Bioimpedance-Based Wearable Applications in Heart Rate Monitoring—A Comprehensive Review
Applied Sciences · 23.08.2024 · 14 (17) · 7451
DOI: 10.3390/app14177451 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 23.08.2024. Verfasst von Didzis Lapsa und 3 weiteren Autor:innen. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 170 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union, Estonian Research Council.
Abstract (Originalsprache)
The monitoring of hemodynamic parameters, such as heart rate and blood pressure, provides valuable indications of overall cardiovascular health. It is preferable that such monitoring is non-invasive and in real time via an affordable, compact and small-scale device for maximum convenience. Numerous literature sources have exploited derivations of these parameters from photoplethysmogram (PPG) and electrical bioimpedance (EBI) signal measurements through the use of calculation algorithms of varying complexity. Compared to electrocardiogram (ECG), these measurement techniques have a merit of well-established practices of designing a wearable device that could conveniently be put on a wrist. The current paper provides a comprehensive review on the use of PPG and EBI measurement techniques in the context of hemodynamic parameter monitoring using a wearable device. A special emphasis is placed on the most basic hemodynamic parameter—heart rate—describing different algorithms of heart rate detection and monitoring. The last section provides an overview of commercially available and in-home wearable device technologies based on PPG and EBI measurements, their design challenges, and future prospects.
Förderung
- European Union
- Estonian Research Council
Zitieren
APA
Lapsa, D., Janeliukstis, R., Metshein, M., & Selavo, L. (2024). PPG and Bioimpedance-Based Wearable Applications in Heart Rate Monitoring—A Comprehensive Review. Applied Sciences, 14(17), 7451. https://doi.org/10.3390/app14177451
Vancouver
Lapsa D, Janeliukstis R, Metshein M, Selavo L. PPG and Bioimpedance-Based Wearable Applications in Heart Rate Monitoring—A Comprehensive Review. Applied Sciences. 2024;14(17):7451. doi:10.3390/app14177451
BibTeX
@article{Lapsa2024,
author = {Lapsa, Didzis and Janeliukstis, Rims and Metshein, Margus and Selavo, Leo},
title = {PPG and Bioimpedance-Based Wearable Applications in Heart Rate Monitoring—A Comprehensive Review},
journal = {Applied Sciences},
year = {2024},
volume = {14},
number = {17},
pages = {7451},
doi = {10.3390/app14177451}
}
EUVIMED