EUVIMEDEUVIMED entdecken
Crossref

Optimization of Fluence Map for CyberKnife Raster Scanning Intensity Modulated Radiotherapy

Yuichi Akino, Hiroya Shiomi, Nobuhisa Mabuchi, Norihisa Masai, Ryoong-Jin Oh, Kazuhiko Ogawa

Anticancer Research · 2023

DOI: 10.21873/anticanres.16314 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Anticancer Research, 2023. Verfasst von Yuichi Akino und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita, Japan; akino@radonc.med.osaka-u.ac.jp. Hauptthemen laut MEDLINE: Radiotherapy, Intensity-Modulated, Prostatic Neoplasms, Radiosurgery.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND/AIM: Stereotactic body radiotherapy for prostate cancer using CyberKnife with circular cone requires a long treatment time. Raster scanning intensity modulated radiotherapy (RS-IMRT) has a potential of improving treatment efficacy, introducing shorter treatment time, better target dose uniformity, and lower organ at risk (OAR) dose. The purpose of the study was to develop a fluence optimization system for RS-IMRT. PATIENTS AND METHODS: RS-IMRT plans were created for five prostate cancer patients treated with the Novalis system and parameters were compared to the Novalis treatment plans. From 80 nodes available for the CyberKnife, twelve nodes were arbitrarily selected. On the beam's eye view of each beam, a 100×100 matrix of optimization points was created at the target center plane. The beam fluence map was optimized using the attraction-repulsion model (ARM). The beam fluence maps were converted to the scanning sequence using the ARM and a final dose calculation was performed. RESULTS: For planning target volume (PTV), RS-IMRT plans showed higher dose covering 2% of the volume (D2%) and lower D98% compared to the Novalis plans. However, the homogeneity was within our Institutional clinical protocol. The RS-IMRT plans showed significantly lower OAR dose parameters including bladder volume receiving 100% of prescribed dose (V100%) and dose delivered to 5 cm3 of rectum (D5 cc). CONCLUSION: We developed a fluence optimization system for RS-IMRT that performs the entire RS-IMRT treatment planning process, including scanning sequence optimization and final dose calculation. The RS-IMRT was capable of generating clinically acceptable plans.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy, Intensity-ModulatedProstatic NeoplasmsRadiosurgeryMaleHumansRadiotherapy Planning, Computer-AssistedRectumEtoposideCarmustineRadiotherapy Dosage

Stichwörter der Autor:innen

CyberKnifeprostate cancerraster scanningstereotactic body radiotherapy

Substanzen

EtoposideCarmustine

Autor:innen und Institutionen

  • Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita, Japan; akino@radonc.med.osaka-u.ac.jp.
  • Soseikai CyberKnife Center, Kyoto, Japan.
  • Miyakojima IGRT Clinic, Osaka, Japan.
  • Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita, Japan.
  • Department of Radiology, Kyoto Prefectural University Graduate School of Medical Science, Kyoto, Japan.

Zitieren

APA

Akino, Y., Shiomi, H., Mabuchi, N., Masai, N., Oh, R. J., & Ogawa, K. (2023). Optimization of Fluence Map for CyberKnife Raster Scanning Intensity Modulated Radiotherapy. Anticancer Research. https://doi.org/10.21873/anticanres.16314

Vancouver

Akino Y, Shiomi H, Mabuchi N, Masai N, Oh RJ, Ogawa K. Optimization of Fluence Map for CyberKnife Raster Scanning Intensity Modulated Radiotherapy. Anticancer Research. 2023. doi:10.21873/anticanres.16314

BibTeX
@article{Akino2023,
  author = {Akino, Yuichi and Shiomi, Hiroya and Mabuchi, Nobuhisa and Masai, Norihisa and Oh, Ryoong-Jin and Ogawa, Kazuhiko},
  title = {Optimization of Fluence Map for CyberKnife Raster Scanning Intensity Modulated Radiotherapy},
  journal = {Anticancer Research},
  year = {2023},
  doi = {10.21873/anticanres.16314}
}
Kostenlos starten →