EUVIMEDEUVIMED entdecken
Open Access

Accuracy of 3 Intraoral Scanners in Recording Impressions for Full Arch Dental Implant-Supported Prosthesis: An In Vitro Study

Saurabh Jain iD, Mohammed E Sayed iD, Reem Abdullah A Khawaji, Ghada Ali J Hakami, Eman Hassan M Solan, Manal A Daish iD, Hossam F Jokhadar, Saad Saleh AlResayes iD, Majed S Altoman iD, Abdullah Hasan Alshehri iD, Saeed M Alqahtani iD, Mohammad Alamri iD und 3 weitere

Medical Science Monitor · 2024

DOI: 10.12659/msm.946624 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Science Monitor, 2024. Verfasst von Saurabh Jain und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia. Hauptthemen laut MEDLINE: Dental Impression Technique, Dental Implants, Dental Prosthesis, Implant-Supported. Die Arbeit wurde bisher 25-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND This study used an edentulous mandibular resin model with 6 parallel osteotomy sites and aimed to compare the accuracy (trueness and precision) of 10 digital impressions using 3 intraoral scanners, the 3Shape TRIOS 5, Medit i700, and Primescan, using Medit Link v3.3.2 software. MATERIAL AND METHODS A model simulating a patient's lower jaw was surgically prepared at 6 parallel sites (implant osteotomy), allowing placement of 6 implant analogues. Matrix-Direct transfer abutments were attached to the analogs, and a reference scan was obtained using a CeramilMap 600 extraoral scanner. Three intraoral scanners (3Shape TRIOS 5, Medit i700, and Primescan) made 10 digital impressions of each model. The data obtained were superimposed and compared using software (Medit Link 3.3.2) to evaluate accuracy. Mean values were statistically analyzed using one-way ANOVA and post hoc Tukey test. Differences were considered significant at a P value of less than 0.05. RESULTS The TRIOS 5 intraoral scanner displayed the lowest deviation for precision (37.8±4.53 μm) and trueness (54.9±11 μm), followed by Medit i700 (precision 40.6±4.17 μm, trueness 60.5±10.9 μm), whereas the highest deviation (precision: 49.1±8.31 μm, trueness: 72.3±10.4 μm) was reported when Primescan intraoral scanner was used for recording impressions of full arch implants. When the 3 intraoral scanners were compared, a statistically significant difference was observed in terms of precision (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Impression TechniqueDental ImplantsDental Prosthesis, Implant-SupportedHumansMandibleComputer-Aided DesignModels, DentalSoftwareDental Arch

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia.
  • Intern Clinic, College of Dentistry, Jazan University, Jazan, Saudi Arabia.
  • Department of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.
  • Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Jeddah, Saudi Arabia.
  • Department of Prosthetic Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
  • Department of Restorative Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia.

ORCID-Profile: Saurabh Jain, Mohammed E Sayed, Manal A Daish, Saad Saleh AlResayes, Majed S Altoman, Abdullah Hasan Alshehri, Saeed M Alqahtani, Mohammad Alamri, Ahid Amer Alshahrani, Hind Ziyad Al-Najjar, Khurshid Mattoo

Zitieren

APA

Jain, S., Sayed, M. E., Khawaji, R. A. A., Hakami, G. A. J., Solan, E. H. M., Daish, M. A., Jokhadar, H. F., AlResayes, S. S., Altoman, M. S., Alshehri, A. H., Alqahtani, S. M., Alamri, M., Alshahrani, A. A., Al-Najjar, H. Z., & Mattoo, K. (2024). Accuracy of 3 Intraoral Scanners in Recording Impressions for Full Arch Dental Implant-Supported Prosthesis: An In Vitro Study. Medical Science Monitor. https://doi.org/10.12659/msm.946624

Vancouver

Jain S, Sayed ME, Khawaji RAA, Hakami GAJ, Solan EHM, Daish MA, et al. Accuracy of 3 Intraoral Scanners in Recording Impressions for Full Arch Dental Implant-Supported Prosthesis: An In Vitro Study. Medical Science Monitor. 2024. doi:10.12659/msm.946624

BibTeX
@article{Jain2024,
  author = {Jain, Saurabh and Sayed, Mohammed E and Khawaji, Reem Abdullah A and Hakami, Ghada Ali J and Solan, Eman Hassan M and Daish, Manal A and Jokhadar, Hossam F and AlResayes, Saad Saleh and Altoman, Majed S and Alshehri, Abdullah Hasan and Alqahtani, Saeed M and Alamri, Mohammad and Alshahrani, Ahid Amer and Al-Najjar, Hind Ziyad and Mattoo, Khurshid},
  title = {Accuracy of 3 Intraoral Scanners in Recording Impressions for Full Arch Dental Implant-Supported Prosthesis: An In Vitro Study},
  journal = {Medical Science Monitor},
  year = {2024},
  doi = {10.12659/msm.946624}
}
Kostenlos starten →