Vergleichsstudie in der Zeitschrift Clinical Implant Dentistry and Related Research, online erschienen am 15.05.2024. Verfasst von Junying Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biologic and Materials Sciences, Division of Prosthodontics, School of Dentistry, University of Michigan, Ann Arbor, Michigan, USA. Hauptthemen laut MEDLINE: Dental Impression Technique. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objective
To assess a newly developed intraoral scan protocol in enhancing the accuracy of complete‐arch implant impressions. Materials and Methods Four impression approaches were applied to the same maxillary edentulous model with 6 implants: (1) intraoral scan (IOS), (2) intraoral scan with scan aid (IOS‐SA), (3) calibrated intraoral scan protocol (CISP), and (4) conventional splinted open‐tray impression (CONV). Each approach was repeated 10 times, and a direct scan of the model with a desktop scanner was used as a reference model. The alignment of scans and the reference model was conducted by two methods: (a) aligning all scan bodies to evaluate the overall fit, and (b) aligning the first and second scan bodies to simulate the Sheffield fit test for passive fitting of multiple implant‐supported prostheses. Linear deviations from the reference model (trueness) and within each group (precision) were analyzed using Python scripts.
Results
When aligned by all scan bodies, the CISP group exhibited comparable mean trueness (38.33 μm) and precision (45.97 μm) to the CONV group (44.30 and 47.92 μm respectively), both of which significantly outperformed the IOS group (86.82 and 83.17 μm, respectively). Furthermore, in the virtual Sheffield fit test, the CISP group achieved the highest levels of mean trueness at the end span (121.7 μm), making a linear deviation reduction of 36.7%, 60%, and 41.4% when compared to the CONV, the IOS, and the IOS‐SA groups, respectively. Moreover, the CISP group (104.3 μm) displayed a remarkable 65, 182, and 86 μm advantage in precision over the CONV, IOS, and IOS‐SA groups, respectively.
Conclusion
CISP demonstrated comparable accuracy to the gold standard, the conventional splinted open‐tray impression. Furthermore, it excelled in the virtual passive fitting test.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biologic and Materials Sciences, Division of Prosthodontics, School of Dentistry, University of Michigan, Ann Arbor, Michigan, USA.
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Michigan, USA.
- State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Department of Dental Technology, West China Hospital of Stomatology, Sichuan University, Cheng…
- Section of Graduate Periodontology, Faculty of Odontology, University Complutense, Madrid, Spain.
ORCID-Profile: Zhaozhao Chen, Hom-Lay Wang
Zitieren
APA
Li, J., Chen, Z., Nava, P., Yang, S., Calatrava, J., & Wang, H. L. (2024). Calibrated intraoral scan protocol ( CISP ) for full‐arch implant impressions: An in vitro comparison to conventional impression, intraoral scan, and intraoral scan with scan‐aid. Clinical Implant Dentistry and Related Research, 26(5), 879-888. https://doi.org/10.1111/cid.13338
Vancouver
Li J, Chen Z, Nava P, Yang S, Calatrava J, Wang HL. Calibrated intraoral scan protocol ( CISP ) for full‐arch implant impressions: An in vitro comparison to conventional impression, intraoral scan, and intraoral scan with scan‐aid. Clinical Implant Dentistry and Related Research. 2024;26(5):879-888. doi:10.1111/cid.13338
BibTeX
@article{Li2024,
author = {Li, Junying and Chen, Zhaozhao and Nava, Paolo and Yang, Shengtao and Calatrava, Javier and Wang, Hom-Lay},
title = {Calibrated intraoral scan protocol ( CISP ) for full‐arch implant impressions: An in vitro comparison to conventional impression, intraoral scan, and intraoral scan with scan‐aid},
journal = {Clinical Implant Dentistry and Related Research},
year = {2024},
volume = {26},
number = {5},
pages = {879--888},
doi = {10.1111/cid.13338}
}
EUVIMED