Fachartikel in der Zeitschrift Water Science & Technology, online erschienen am 15.04.2025. Verfasst von Salini Pottekkatt und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biotechnology, Sahrdaya College of Engineering & Technology, Kodakara, Thrissur, Kerala, India. Hauptthemen laut MEDLINE: Ultraviolet Rays, Wastewater, Hydrogen Peroxide, Waste Disposal, Fluid. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Automobile service stations are a significant contributor to environmental issues due to the release of harmful wastewater containing various pollutants like oils, grease, detergents, and organic and inorganic substances. Our study focused on treating this wastewater through both biological and UV-Fenton methods to target the removal of chemical oxygen demand (COD), turbidity, and oil and grease for potential reuse. In the biological approach, we isolated diverse microorganisms from the wastewater, and the predominant microorganism identified through 16S rRNA sequencing was Pseudomonas aeruginosa. Key parameters, including pH (6.2) and incubation time (45.6 h), were optimized using response surface methodology (RSM) to enhance pollutant degradation. The microorganisms were immobilized on biofilm carriers, achieving significant reductions: 83% COD, 93% turbidity, and 67% oil and grease. For the second method, we employed a UV-Fenton-based advanced oxidation process, optimizing Fe2+ dosage (42.4 mg/L) and H2O2 concentration (412.1 mg/L). This process demonstrated substantial reductions: 89% COD, 95% turbidity, and 72% oil and grease. Combining both biological and UV-Fenton treatments in series yielded even better outcomes with reductions of 89% COD, 96% turbidity, and 78% oil and grease. This integrated approach proved highly effective in meeting wastewater quality standards, demonstrating significant pollutant reduction within acceptable limits.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ultraviolet RaysWastewaterHydrogen PeroxideWaste Disposal, FluidAutomobilesIronWater PurificationBiological Oxygen Demand AnalysisPseudomonas aeruginosaWater Pollutants, Chemical

Stichwörter der Autor:innen

RSMUV Fentonautomobile service station wastewaterbiofilm carriersmicroorganismsrRNA sequencing

Substanzen

WastewaterHydrogen PeroxideIronFenton's reagentWater Pollutants, Chemical

Autor:innen und Institutionen

  • Department of Biotechnology, Sahrdaya College of Engineering & Technology, Kodakara, Thrissur, Kerala, India.
  • School of Engineering, Cochin University of Science and Technology, Kochi, Kerala, India E-mail: salinipj@sahrdaya.ac.in.
  • School of Engineering, Cochin University of Science and Technology, Kochi, Kerala, India.

ORCID-Profile: Salini Pottekkatt

Zitieren

APA

Pottekkatt, S., George, J., Zakkariya, R., P N, C., Nair, G., Gopal, M., & Pawels, R. (2025). Integrated biological and UV-Fenton processes for the treatment of automobile service station wastewater. Water Science & Technology, 91(8), 977-992. https://doi.org/10.2166/wst.2025.054

Vancouver

Pottekkatt S, George J, Zakkariya R, P N C, Nair G, Gopal M, et al. Integrated biological and UV-Fenton processes for the treatment of automobile service station wastewater. Water Science & Technology. 2025;91(8):977-992. doi:10.2166/wst.2025.054

BibTeX
@article{Pottekkatt2025,
  author = {Pottekkatt, Salini and George, Jennipher and Zakkariya, Riya and P N, Christo and Nair, Gouri and Gopal, Madhu and Pawels, Renu},
  title = {Integrated biological and UV-Fenton processes for the treatment of automobile service station wastewater},
  journal = {Water Science & Technology},
  year = {2025},
  volume = {91},
  number = {8},
  pages = {977--992},
  doi = {10.2166/wst.2025.054}
}
Kostenlos starten →