Combining Electro Fenton With Adsorption Processes for Treatment of Petroleum Refinery Wastewater
Water Environment Research · 2025
DOI: 10.1002/wer.70185 ↗Kurz gefasst
Fachartikel in der Zeitschrift Water Environment Research, 2025. Verfasst von Ali N Kassob und 4 weiteren Autor:innen. Beteiligte Einrichtung: Chemical Engineering Department, College of Engineering, University of Al-Qadisiyah, Al-Diwaniyah, Iraq. Hauptthemen laut MEDLINE: Wastewater, Petroleum, Waste Disposal, Fluid, Iron. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 79 Literaturangaben.
Abstract (Originalsprache)
This study investigates the elimination of chemical oxygen demand (COD) from an Iraqi petroleum refinery effluent through a combined electro‐Fenton and adsorption process (EF+AC). Response surface methodology (RSM) with a Box–Behnken design (BBD) was employed to investigate the effects of FeSO 4 concentration, current density, and electrolysis time on the reduction of COD using the EF technique. According to the results of the analysis of variance (ANOVA) for the EF technique, FeSO 4 concentrations, with a contribution of 40.06%, and current density, with a contribution of 46.35%, exert a considerable influence. The optimum conditions for COD elimination rate (99.06%) and energy consumption (9.805 kWh/kg COD) were achieved using an electrolysis time of 85.12 min, a current density of 25 mA/cm 2 , and a concentration of 1.335 mM FeSO 4 . For the EF+AC process, a central composite design (CCD) was used to determine the influence of the packing level of activated carbon (AC) and the time on the reduction of COD at a constant current density of 5 mA/cm 2 and FeSO 4 concentration of 0.2 mM. The packing level of AC significantly influenced the elimination of COD, with time being the subsequent factor. The results showed that the optimal conditions led to a 98.77% removal of COD, requiring 0.91 kWh/kg COD. This efficiency and energy consumption were attained by using 92% packed AC and allowing the process to run for 85 min. EF+AC was found to have lower energy consumption and a smaller quantity of ferrous sulfate compared to EF. Notably, the current system offers a promising vision by combining the benefits of adsorption and electro‐Fenton for wastewater remediation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Chemical Engineering Department, College of Engineering, University of Al-Qadisiyah, Al-Diwaniyah, Iraq.
- Department of Biochemical Engineering, Al-Khwarizmi College of Engineering, University of Baghdad, Baghdad, Iraq.
- Civil Engineering Department, College of Engineering, University of Al-Qadisiyah, Al-Qadisiyah, Al-Diwaniyah, Iraq.
- Department of Oil and Gas Refining Engineering, Al Hikma University College, Baghdad, Iraq.
- School of Chemical Engineering, University of Birmingham, Birmingham, UK.
- Department of Environmental Engineering, College of Engineering, Mustansiriyah University, Baghdad, Iraq.
ORCID-Profile: Ali H Abbar, Abdullah Y Ghjeer
Zitieren
APA
Kassob, A. N., Abbar, A. H., Ghjeer, A. Y., Jabbar, Z. H., & Al-Sharify, Z. T. (2025). Combining Electro Fenton With Adsorption Processes for Treatment of Petroleum Refinery Wastewater. Water Environment Research. https://doi.org/10.1002/wer.70185
Vancouver
Kassob AN, Abbar AH, Ghjeer AY, Jabbar ZH, Al-Sharify ZT. Combining Electro Fenton With Adsorption Processes for Treatment of Petroleum Refinery Wastewater. Water Environment Research. 2025. doi:10.1002/wer.70185
BibTeX
@article{Kassob2025,
author = {Kassob, Ali N and Abbar, Ali H and Ghjeer, Abdullah Y and Jabbar, Zaid H and Al-Sharify, Zainab T},
title = {Combining Electro Fenton With Adsorption Processes for Treatment of Petroleum Refinery Wastewater},
journal = {Water Environment Research},
year = {2025},
doi = {10.1002/wer.70185}
}
EUVIMED