EUVIMEDSkopri EUVIMED
Open access · CC BY-NC 3.0

Tip design for safety of steerable needles for robot-controlled brain insertion

Craig A Lehocky, Wendy Fellows-Mayle, Johnathan A Engh, Cameron N Riviere

Robotic Surgery: Research and Reviews · 2017

DOI: 10.2147/rsrr.s141085 ↗

At a glance

Journal article in Robotic Surgery: Research and Reviews, 2017. Written by Craig A Lehocky and 3 co-authors. Institution: Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA. Cited 2 times so far (Crossref). The full text is freely available (open access, CC BY-NC 3.0). Funded by: NIBIB NIH HHS.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

BACKGROUND: Current practice in neurosurgical needle insertion is limited by the straight trajectories inherent with rigid probes. One technique allowing curvilinear trajectories involves flexible bevel-tipped needles, which bend during insertion due to their asymmetry. In the brain, safety will require avoidance of the sharp tips often used in laboratory studies, in favor of a more rounded profile. Steering performance, on the other hand, requires maximal asymmetry. Design of safe bevel-tipped brain needles thus involves management of this tradeoff by adjusting needle gauge, bevel angle, and fillet (or tip) radius to arrive at a design that is suitably asymmetrical while producing strain, strain rate, and stress below the levels that would damage brain tissue. METHODS: Designs with a variety of values of needle radius, bevel angle, and fillet radius were evaluated in finite-element simulations of simultaneous insertion and rotation. Brain tissue was modeled as a hyperelastic, linear viscoelastic material. Based on the literature available, safety thresholds of 0.19 strain, 10 s-1 strain rate, and 120 kPa stress were used. Safe values of needle radius, bevel angle, and fillet radius were selected, along with an appropriate velocity envelope for safe operation. The resulting needle was fabricated and compared with a Sedan side-cutting brain biopsy needle in a study in the porcine model in vivo (N=3). RESULTS: The prototype needle selected was 1.66 mm in diameter, with bevel angle of 10° and fillet radius of 0.25 mm. Upon examination of postoperative CT and histological images, no differences in tissue trauma or hemorrhage were noted between the prototype needle and the Sedan needle. CONCLUSIONS: The study indicates a general design technique for safe bevel-tipped brain needles based on comparison with relevant damage thresholds for strain, strain rate, and stress. The full potential of the technique awaits the determination of more exact safety thresholds.

Subjects

Author keywords

Robotic surgerybevel-tipped needlefinite element analysisneedle steeringstr ainstrain ratestress

Authors and institutions

  • Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA.
  • Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
  • The Robotics Institute, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA.

Funding

  • NIBIB NIH HHS

Cite

APA

Lehocky, C. A., Fellows-Mayle, W., Engh, J. A., & Riviere, C. N. (2017). Tip design for safety of steerable needles for robot-controlled brain insertion. Robotic Surgery: Research and Reviews. https://doi.org/10.2147/rsrr.s141085

Vancouver

Lehocky CA, Fellows-Mayle W, Engh JA, Riviere CN. Tip design for safety of steerable needles for robot-controlled brain insertion. Robotic Surgery: Research and Reviews. 2017. doi:10.2147/rsrr.s141085

BibTeX
@article{Lehocky2017,
  author = {Lehocky, Craig A and Fellows-Mayle, Wendy and Engh, Johnathan A and Riviere, Cameron N},
  title = {Tip design for safety of steerable needles for robot-controlled brain insertion},
  journal = {Robotic Surgery: Research and Reviews},
  year = {2017},
  doi = {10.2147/rsrr.s141085}
}
Start for free →