Tip design for safety of steerable needles for robot-controlled brain insertion
Robotic Surgery: Research and Reviews · 2017
DOI: 10.2147/rsrr.s141085 ↗Kurz gefasst
Fachartikel in der Zeitschrift Robotic Surgery: Research and Reviews, 2017. Verfasst von Craig A Lehocky und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA. Die Arbeit wurde bisher 2-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0). Gefördert von: NIBIB NIH HHS.
Abstract (Originalsprache)
BACKGROUND: Current practice in neurosurgical needle insertion is limited by the straight trajectories inherent with rigid probes. One technique allowing curvilinear trajectories involves flexible bevel-tipped needles, which bend during insertion due to their asymmetry. In the brain, safety will require avoidance of the sharp tips often used in laboratory studies, in favor of a more rounded profile. Steering performance, on the other hand, requires maximal asymmetry. Design of safe bevel-tipped brain needles thus involves management of this tradeoff by adjusting needle gauge, bevel angle, and fillet (or tip) radius to arrive at a design that is suitably asymmetrical while producing strain, strain rate, and stress below the levels that would damage brain tissue. METHODS: Designs with a variety of values of needle radius, bevel angle, and fillet radius were evaluated in finite-element simulations of simultaneous insertion and rotation. Brain tissue was modeled as a hyperelastic, linear viscoelastic material. Based on the literature available, safety thresholds of 0.19 strain, 10 s-1 strain rate, and 120 kPa stress were used. Safe values of needle radius, bevel angle, and fillet radius were selected, along with an appropriate velocity envelope for safe operation. The resulting needle was fabricated and compared with a Sedan side-cutting brain biopsy needle in a study in the porcine model in vivo (N=3). RESULTS: The prototype needle selected was 1.66 mm in diameter, with bevel angle of 10° and fillet radius of 0.25 mm. Upon examination of postoperative CT and histological images, no differences in tissue trauma or hemorrhage were noted between the prototype needle and the Sedan needle. CONCLUSIONS: The study indicates a general design technique for safe bevel-tipped brain needles based on comparison with relevant damage thresholds for strain, strain rate, and stress. The full potential of the technique awaits the determination of more exact safety thresholds.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA.
- Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
- The Robotics Institute, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA.
Förderung
- NIBIB NIH HHS
Zitieren
APA
Lehocky, C. A., Fellows-Mayle, W., Engh, J. A., & Riviere, C. N. (2017). Tip design for safety of steerable needles for robot-controlled brain insertion. Robotic Surgery: Research and Reviews. https://doi.org/10.2147/rsrr.s141085
Vancouver
Lehocky CA, Fellows-Mayle W, Engh JA, Riviere CN. Tip design for safety of steerable needles for robot-controlled brain insertion. Robotic Surgery: Research and Reviews. 2017. doi:10.2147/rsrr.s141085
BibTeX
@article{Lehocky2017,
author = {Lehocky, Craig A and Fellows-Mayle, Wendy and Engh, Johnathan A and Riviere, Cameron N},
title = {Tip design for safety of steerable needles for robot-controlled brain insertion},
journal = {Robotic Surgery: Research and Reviews},
year = {2017},
doi = {10.2147/rsrr.s141085}
}
EUVIMED