EUVIMEDOpdag EUVIMED
Crossref

Dual-band Noncontact Doppler Radar System for Pulse Measurement with K- and X-Band Frequencies

Wei-Lung Wu

Sensors and Materials · 2026-06-02 · 38 (6) · 2953

DOI: 10.18494/sam6278 ↗

At a glance

Journal article in Sensors and Materials, published on 2026-06-02. Written by Wei-Lung Wu.

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

In this study, we developed a dual-frequency radar measurement system that exploits the Doppler effect and microdisplacement-induced echo phase variations. The system detects targets by using two frequency bands simultaneously: the 24 GHz (phased antenna array) and 12 GHz (conical antenna array) bands. This dual-frequency radar system enables the precise, noncontact measurement of physiological signals, including heartbeat and respiration, as well as minor variations in pulse and vascular contraction. Compared with single-frequency, unidirectional radar measurements, the proposed system’s measurements showed inter-band agreement during repeated validation. Dual-frequency measurement enables the cross-comparison and verification of data, exhibiting high consistency while optimizing the trade-off among sensitivity, penetration, measurement range, and robustness to body motion. The proposed system demonstrates the feasibility of noncontact, dual-frequency radar-based physiological monitoring under minimal pulse variation. Pearson correlation coefficient ( r ) analysis was used to quantify the linear consistency between the 12 and 24 GHz measurements, yielding an r value of 0.82096, a 95% confidence interval of 0.80756–0.83351 (estimated using Fisher’s z -transform), and a two-tailed p value considerably below 0.001. These results indicate that the dual-frequency radar sequences are highly synchronized in amplitude trends and exhibit strong linear consistency, providing a reliable basis for cross-validation and data fusion.

Cite

APA

Wu, W. (2026). Dual-band Noncontact Doppler Radar System for Pulse Measurement with K- and X-Band Frequencies. Sensors and Materials, 38(6), 2953. https://doi.org/10.18494/sam6278

Vancouver

Wu W. Dual-band Noncontact Doppler Radar System for Pulse Measurement with K- and X-Band Frequencies. Sensors and Materials. 2026;38(6):2953. doi:10.18494/sam6278

BibTeX
@article{Wu2026,
  author = {Wu, Wei-Lung},
  title = {Dual-band Noncontact Doppler Radar System for Pulse Measurement with K- and X-Band Frequencies},
  journal = {Sensors and Materials},
  year = {2026},
  volume = {38},
  number = {6},
  pages = {2953},
  doi = {10.18494/sam6278}
}
Start for free →