EUVIMEDEUVIMED entdecken
Crossref

Noncontact Infant Apnea Detection for Hypoxia Prevention With a K -Band Biomedical Radar

Li Wen, Shuqin Dong, Yi Wang, Changzhan Gu, Zheng Tang, Zhiwei Liu, Yanfeng Wang, Junfa Mao

IEEE Transactions on Biomedical Engineering · 2024-03 · 71 (3) · 1022-1032

DOI: 10.1109/tbme.2023.3325468 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2024-03. Verfasst von Li Wen und 7 weiteren Autor:innen. Hauptthemen laut MEDLINE: Radar, Sleep Apnea Syndromes. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Medical Research Ethics Committee of International Peace Maternity and Child Health Hospital, National Natural Science Foundation of China, Shanghai Jiao Tong University Medical-Engineering Interdisciplinary Research Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Annually, a significant number of premature infants suffer from apnea, which can easily cause a drop in oxygen saturation levels, leading to hypoxia. However, infant cardiopulmonary monitoring using conventional methods often necessitates skin contact, and they are not suitable for long-term monitoring. This article introduces a non-contact technique for infant cardiopulmonary monitoring and an adjustable apnea detection algorithm. These are developed using a custom-designed K-band continuous-wave biomedical radar sensor system, which features a DC-coupled adaptive digital tuning function. By using radar technology to detect chest motions without physical contact, it is feasible to extract significant biological information regarding an infant's respiration and heartbeat. The proposed algorithm utilizes an adaptively adjusted threshold and personalized apnea warning time to automatically measure the total number of apneic events and their respective durations. Experiments have been conducted in clinical environment, demonstrating that both the accurate cardiopulmonary signals and the apneas of varying durations can be effectively monitored using this method, which suggest that the proposed technique has potential applications both inside and outside of clinical settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadarSleep Apnea SyndromesHumansRespirationHeart RateHeartAlgorithmsSignal Processing, Computer-Assisted

Förderung

  • Medical Research Ethics Committee of International Peace Maternity and Child Health Hospital
  • National Natural Science Foundation of China
  • Shanghai Jiao Tong University Medical-Engineering Interdisciplinary Research Fund
  • Clinical Research Plan of SHDC

Zitieren

APA

Wen, L., Dong, S., Wang, Y., Gu, C., Tang, Z., Liu, Z., Wang, Y., & Mao, J. (2024). Noncontact Infant Apnea Detection for Hypoxia Prevention With a K -Band Biomedical Radar. IEEE Transactions on Biomedical Engineering, 71(3), 1022-1032. https://doi.org/10.1109/tbme.2023.3325468

Vancouver

Wen L, Dong S, Wang Y, Gu C, Tang Z, Liu Z, et al. Noncontact Infant Apnea Detection for Hypoxia Prevention With a K -Band Biomedical Radar. IEEE Transactions on Biomedical Engineering. 2024;71(3):1022-1032. doi:10.1109/tbme.2023.3325468

BibTeX
@article{Wen2024,
  author = {Wen, Li and Dong, Shuqin and Wang, Yi and Gu, Changzhan and Tang, Zheng and Liu, Zhiwei and Wang, Yanfeng and Mao, Junfa},
  title = {Noncontact Infant Apnea Detection for Hypoxia Prevention With a K -Band Biomedical Radar},
  journal = {IEEE Transactions on Biomedical Engineering},
  year = {2024},
  volume = {71},
  number = {3},
  pages = {1022--1032},
  doi = {10.1109/tbme.2023.3325468}
}
Kostenlos starten →