Fachartikel in der Zeitschrift International Journal of Ophthalmology, erschienen am 18.07.2024. Verfasst von Humberto Carreras-Díaz und 3 weiteren Autor:innen. Beteiligte Einrichtung: Vithas Eurocanarias, Las Palmas de Gran Canaria 35004, Spain. Die Arbeit wurde bisher 4-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
AIM: To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port (V4c T-ICL) implantation over 1y of follow-up. METHODS: A retrospective study was performed including 50 eyes of 50 patients that underwent V4c T-ICL implantation. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, refractive and corneal astigmatism changes and corneal coupling correction were evaluated preoperatively, 1 and 12mo postoperatively. Vector analysis was used for astigmatism changes. Coefficient of adjustment (CAdj) was calculated for corneal coupling analysis. RESULTS: The mean UDVA achieved was 0.03 logMAR at 1mo and remained unchanged throughout the whole follow-up (P=0.193). At the last visit, 84% of the eyes achieved a CDVA of 0.00 logMAR or better. Regarding spherical equivalent refraction (SEQ), 96% of eyes were ranges of ±1.00 D and 84% of them within ±0.50 D. Also, 94% of eyes had a remaining refractive cylinder within ±1.00 D and 78% of them within ±0.50 D. Both, SEQ and refractive cylinder, remain stable over the postoperative follow-up (P=1.000 and P=0.660, respectively). In terms of surgically induced astigmatism (SIA), no statistically significant differences were found over the follow-up (P=0.102) and under correction was found with a correction index lower than the unit at each visit. A keratometric astigmatism induced of 0.59±0.53 (vector mean: 0.26×73º) D was reached at the last visit. No significant changes in terms of corneal astigmatism orientation were reported over post-surgery visits (P=0.129 and P=0.097 at 1 and 12mo respectively). No clinical significance was found for CAdj on with-the-rule astigmatism. No postoperative complications resulting from the surgery were found. CONCLUSION: Refractive outcomes suggest that the V4c T-ICL implantation for correction of myopic astigmatism was satisfactory in terms of effectiveness, safety, and stability during 1y of follow-up. Corneal astigmatism induced by the incision around 0.5 D is achieved according to the remaining refractive cylinder found at one-year post-surgery. Corneal coupling analysis results in no unexpected spherical change.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Vithas Eurocanarias, Las Palmas de Gran Canaria 35004, Spain.
- University Hospital of Girona Doctor Josep Trueta, Gerona 17007, Spain.
- Departament of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid 28040, Spain.
Zitieren
APA
Carreras-Díaz, H., Reñones de Abajo, J., Carreras-Díaz, M. D. R., & Lorente-Velázquez, A. (2024). Refractive outcomes after V4c Toric collamer lens implantation over 1y of follow-up. International Journal of Ophthalmology, 17(7), 1322-1330. https://doi.org/10.18240/ijo.2024.07.18
Vancouver
Carreras-Díaz H, Reñones de Abajo J, Carreras-Díaz MDR, Lorente-Velázquez A. Refractive outcomes after V4c Toric collamer lens implantation over 1y of follow-up. International Journal of Ophthalmology. 2024;17(7):1322-1330. doi:10.18240/ijo.2024.07.18
BibTeX
@article{CarrerasDaz2024,
author = {Carreras-Díaz, Humberto and Reñones de Abajo, Josefina and Carreras-Díaz, María Del Rosario and Lorente-Velázquez, Amalia},
title = {Refractive outcomes after V4c Toric collamer lens implantation over 1y of follow-up},
journal = {International Journal of Ophthalmology},
year = {2024},
volume = {17},
number = {7},
pages = {1322--1330},
doi = {10.18240/ijo.2024.07.18}
}
EUVIMED