EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Changes of dysfunctional lens index before and after implantable collamer lens V4c implantation in patients with moderate-to-high myopia

Weifang Cao, Suhua Zhang, Qian Liu, Jing Zhou, Xiaoyong Yuan

International Ophthalmology · 22.07.2023 · 43 (11) · 4111-4120

DOI: 10.1007/s10792-023-02812-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Ophthalmology, online erschienen am 22.07.2023. Verfasst von Weifang Cao und 4 weiteren Autor:innen. Beteiligte Einrichtung: Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, 300070, China. Hauptthemen laut MEDLINE: Lenses, Intraocular, Lens, Crystalline, Myopia. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Dysfunctional lens index (DLI) changing is rarely reported after implantable collamer lens (ICL) implantation. In the current research, we hope to investigate the changes of DLI by ray-tracing aberrometry before and after implantation of the posterior chamber phakic implantable collamer lens with a central artificial hole for patients with moderate-to-high myopia.

Methods

This retrospective, observational case series included 206 eyes of 104 patients with moderate-to-high myopia who underwent ICL V4c implantation. Data were collected on ocular indicators preoperatively and at 1 day, 1, 3, and 6 months postoperatively. The i-Trace Visual Functional Analyzer was used to assess the DLI measurement.

Results

The overall values of safety index and efficacy index were both more than 1. Preoperatively, the mean spherical equivalent (SE) of included 206 eyes was − 10.77 ± 3.46 diopter (D). Then at 1-day postoperation, the mean SE was − 0.22 ± 0.55 D, and barely changed from 1 day to 6 months postoperatively. Although the endothelial parameters had no significant differences between preoperation and postoperation, the mean loss of endothelial cells was 0.74 ± 0.98% at 6 months. Regarding the vault, there was a significant difference between each time of follow-up ( P < 0.001). The mean of the vault decreased 109.6 ± 13.5 µm from 1-day post-op to 6 months post-op. The DLI values were 3.70, 9.26, 10.00, and 9.68 at baseline, 1, 3, and 6 months, respectively ( P < 0.001), but no significant differences were found between 1, 3, and 6 months postoperatively ( P > 0.05). The preoperative lnDLI showed a significant positive linear correlation ( r = 0.621, P < 0.001) with the preoperative spherical equivalent (SE). The lnDLI was negatively correlated with the axial length ( r = − 0.462, P < 0.001), corneal thickness ( r = − 0.207, P = 0.003), preoperative LogMAR UDVA ( r = − 0.189, P = 0.006), and preoperative LogMAR CDVA ( r = − 0.306, P < 0.001).

Conclusions

The postoperative refractive parameters were confirmed excellent in efficacy, predictability, and stability in half a year. The DLI was significantly improved after the ICL V4c implantation in patients with moderate-to-high myopia and showed good stability during the follow-up periods. The DLI deserves a more comprehensive understanding and application in clinical services.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lenses, IntraocularLens, CrystallineMyopiaHumansEndothelial CellsRetrospective Studies

Stichwörter der Autor:innen

Dysfunctional lens indexModerate-to-high myopiaPhakic intraocular lensRefractive surgery

Autor:innen und Institutionen

  • Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, 300070, China.
  • Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Tianjin, 300020, China.
  • Department of Cataract, Shanxi Eye Hospital, Taiyuan, 030002, Shanxi Province, China.
  • Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, 300070, China. yuanxy_cn@hotmail.com.
  • Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Tianjin, 300020, China. yuanxy_cn@hotmail.com.

Zitieren

APA

Cao, W., Zhang, S., Liu, Q., Zhou, J., & Yuan, X. (2023). Changes of dysfunctional lens index before and after implantable collamer lens V4c implantation in patients with moderate-to-high myopia. International Ophthalmology, 43(11), 4111-4120. https://doi.org/10.1007/s10792-023-02812-0

Vancouver

Cao W, Zhang S, Liu Q, Zhou J, Yuan X. Changes of dysfunctional lens index before and after implantable collamer lens V4c implantation in patients with moderate-to-high myopia. International Ophthalmology. 2023;43(11):4111-4120. doi:10.1007/s10792-023-02812-0

BibTeX
@article{Cao2023,
  author = {Cao, Weifang and Zhang, Suhua and Liu, Qian and Zhou, Jing and Yuan, Xiaoyong},
  title = {Changes of dysfunctional lens index before and after implantable collamer lens V4c implantation in patients with moderate-to-high myopia},
  journal = {International Ophthalmology},
  year = {2023},
  volume = {43},
  number = {11},
  pages = {4111--4120},
  doi = {10.1007/s10792-023-02812-0}
}
Kostenlos starten →